11. Error codes (error codes description with possible solutions)
Error codes description with possible solutions:
ERROR
CODE
DISPLAY
DESCRIPTION
ERROR DESCRIPTION
TROUBLESHOOTING
1.
Err
XX-01
TRV paired with thermostat - TRV
hardware error.
• Reinstall the TRV head or replace it. If necessary, contact with the
SALUS Technical Department.
2.
Err
XX-02
Floor is overheated (heating mode).
/ Floor is overcooled (in cooling
mode).
• Set the heating medium temperature or change D14 parameter.
• Set the cooling medium temperature or change D16 parameter.
3.
Err
XX-03
Floor sensor is broken.
• If floor sensor is connected to S1/S2 input, check the wiring.
• If floor sensor is not connected, check the D03/D04 parameters settings.
4.
Err
XX-04
Floor sensor is shorted.
• Check floor sensor wire insulation for any damages. Sensor resistance for
25°C=10kΩ.
5.
Err
XX-05
Thermostat lost contact with the
CO10RF network coordinator or the
UGE600 internet gateway.
• Check the coordinator/gateway power supply connection.
• Force identification process from the coordinator/gateway or thermostat.
6.
Err
XX-06
Thermostat lost connection with the
wiring centre.
Is the wiring centre turned ON and Status Network LED diode solid?
• If yes, send the heating signal from thermostat to the wiring centre
Thermostat constantly monitors the network status, wireless connection status and the operation of connected sensors or paired devices. If it detects any
failure then following error codes can be displayed alternately with the current room temperature value.
Number of errors
Error code
In Online mode error is also shown in the Smart Home application (with
detailed description). Exclamation mark informs user about existing errors.
PLEASE NOTE!