background image

56

Now thermostat is looking for the 

signal from the coordinator...

7.3 Pairing with wireless TRV radiator head

On the LCD you will see the number of 

paired TRV’s. Once all TRV’s are paired - 

press      button to finish the pairing 

process. 

 

PLEASE NOTE!

For easier installation, please make sure you have already added wireless TRV radiator heads to your ZigBee network (please refer to the wireless TRV 
radiator head manual instruction).

1

4

7

8

9

2

Set your thermostat for radiators 

by „

”  or  „

” buttons. 

Confirm by    button.

3

Open the ZigBee network.

OR

 5 sec.

 5 sec.

Thermostat is searching for TRVs 

radiator heads...

5

6

Hold the button           for 10 seconds,

The LED on the head should start  

to blink 

red

. You can pair up to 6 TRV’s with 1 

thermostat. All TRV’s have to be within the 

same room with thermostat. 

 10 sec

Device is paired with coordinator, 

diode on the TRV will start to blink 

orange

.

Diode on the TRV will light up once

 

green

 and stop blinking.

The thermostat has been added to the ZigBee 

network and paired with the gateway/

coordinator. Press    button to confirm.

Summary of Contents for HTRP-RF

Page 1: ...HTRP RF 50 THERMOSTAT FULL USER MANUAL ...

Page 2: ...t Plug SPE600 17 5 5 Pairing with Smart Relay SR600 19 5 6 Pairing with RX10RF receiver 21 6 OPERATING in ONLINE MODE by app 23 6 1 General informations 23 6 2 App icons description 23 6 3 Change thermostat name pencil icon 24 6 4 Setpoint temperature change 25 6 5 Heat Cool mode change KL08RF connection 26 6 6Thermostat modes 27 6 6 1 Schedule mode 27 6 6 2Temporary override mode 31 6 6 3 Manual ...

Page 3: ...ne assigned to another thermostat 55 7 3 Pairing with wirelessTRV radiator head 56 7 4 Pairing with RX10RF receiver 58 8 OPERATING in OFFLINE MODE 59 8 1Work modes 59 8 2 Heat cool mode change KL08RF connection 60 8 3 User settings basic settings 61 8 3 1 Schedule mode programming schedule 61 8 3 2Time Date 63 8 3 3Thermostat calibration 64 8 3 4 Key lock function 65 9 Installer parameters 66 10 F...

Page 4: ......

Page 5: ...ations in accordance with standards and regulations in force in the given country and in the EU Never try to connect the device other than as described in the manual Before assembly repair or maintenance as well as during any connection works it is absolutely necessary disconnect the mains supply and make sure that the terminals and electric wires are not live The device may not be exposed to extr...

Page 6: ... RX10RF boiler receiver In combination with Universal Gateway UGE600 this regulator can be controlled over the Internet using SALUS SmartHomeapp Onlinemode WithoutInternetconnection Offlinemode thermostatworkslocally butitscommunicationwithotherdevicesmustbe done through the coordinating unit CO10RF Full version of the PDF manual instruction is available on the website www salus controls eu The id...

Page 7: ...nreliability detectionand removal of transmission errors as well as connectivity between established priority devices Security measures include devices authenticated using a unique key pair encrypted communication between the mobile application and the device data encryption HTTPS encrypted usingTLS UDP channel with AES 128 encryption layered access control to prevent tampering with one device thr...

Page 8: ...twork coordinator toinstallanduseyourdevices UniversalGatewayisNOT CONNECTEDTOTHEINTERNET You can use your devices locally withouttheSmartHomeApp Gateway works in this mode as standard ZigBee coordinator Compatibiledevices KL08RFwireless wiring centre for 8 zone underfloor heating KL04RFextension TRV Thermostatic Radiator Valve with wireless communication RX10RF receiver SR600 Smart Relay SPE600 S...

Page 9: ...o enter installer parameter settings 4 Before you start first power up 4 2 Button description 4 1 LCD icon description 1 Comfort temperature 2 Standard temperature 3 Economic temperature 4 Automatic mode 5 PARTY mode 6 Holiday mode 7 Frost protection mode 8 Temperature unit 9 Heating mode ON 10 Gateway wireless connection 11 Internet connection indicator 12 Cooling mode ON 13 Manual mode override ...

Page 10: ...ically power up and start boot sequence Set your thermostat for underfloor heating or radiator heating by or buttons Then confirm by button it will display all icons then thermostat will display the software version Remove the protection foil and insert 2xAA batteries by removing back cover 3 2 1 5 4 ...

Page 11: ...sure that you have downloaded the Salus Smart Home App from the Google Play or App Store You will need to follow a few easy steps to create an account and then link your thermostat to the Universal Gateway and to the App You can also access the web version on http eu salusconnect io TobeginthepairingprocesstheGatewayshouldbepluggedintothepowersupplyandconnectedtothe Internet Also makesurethattheUG...

Page 12: ...uipment Press Scan for equipment button 7 8 App has started scanning 1 2 For easier installation please make sure you have already added underfloor heating wiring centre KL08RF Control Box to your ZigBee network please refer to the underfloor heating wiring centre manual instruction Please note Set your thermostat for underfloor heating by or buttons Then confirm by button 9 Gateway has started fl...

Page 13: ... added before Choose UFHWiring Centre option Thermostat is connected Go to the Smart Home app to configure it 10 Select your thermostat and press Connect equipment button Name your thermostat and go Next Press gear icon 11 12 13 14 15 ...

Page 14: ...ontrol Box 3 Gateway stop flashing and turn to steady blue color which means pair process has been finished Press Finish button to end the set up process in the app Choose No if you want to set your own schedule later or Yes if default now Select the zone which you want attribute to your thermostat 17 18 19 20 16 ...

Page 15: ...nnected Go to the Smart Home app to configure it Press Scan for equipment button 7 8 App has started scanning 2 For easier installation please make sure you have already added wireless TRV radiator heads to your ZigBee network please refer to the wireless TRV radiator head manual instruction Please note Set your thermostat for radiators by or buttons Then confirm by button 9 Gateway has started fl...

Page 16: ... which means pair process has been finished Press Finish button to end the set up process in the app Choose No if you want to set your own schedule later or Yes if default now Select yourTRV radiator head from the list Now choose Smart Radiator Control 17 13 14 15 16 Select your thermostat and press Connect equipment button Name your thermostat and go Next Press gear icon 10 11 12 ...

Page 17: ...equipment button 7 8 App has started scanning 2 For easier installation please make sure you have already added Smart Plug SPE600 to your ZigBee network please refer to the Smart Plug SPE600 manual instruction Please note Set your thermostat for underfloor heating by or buttons Then confirm by button Thermostat is connected Go to the Smart Home app to configure it 9 Gateway has started flashing re...

Page 18: ... color which means pair process has been finished Press Finish button to end the set up process in the app Choose No if you want to set your own schedule later or Yes if default now Select your Smart Plug from the list Now choose Smart Plug Select your thermostat and press Connect equipment button Name your thermostat and go Next Press gear icon 10 11 12 17 16 13 14 15 ...

Page 19: ...equipment button 7 8 App has started scanning 2 For easier installation please make sure you have already added Smart Relay SR600 to your ZigBee network please refer to the Smart Relay SR600 manual instruction Please note Set your thermostat for underfloor heating by or buttons Then confirm by button Thermostat is connected Go to the Smart Home app to configure it 9 Gateway has started flashing re...

Page 20: ...color which means pair process has been finished Select your Smart Relay from the list Now choose Smart Relay Select your thermostat and press Connect equipment button Name your thermostat and go Next Press gear icon 10 11 12 17 16 Choose No if you want to set your own schedule later or Yes if default now 13 14 15 Press Finish button to end the set up process in the app ...

Page 21: ...or equipment button 7 8 App has started scanning 2 For easier installation please make sure you have already added RX10RF receiver to your ZigBee network please refer to the RX10RF receiver manual instruction Please note Set your thermostat for underfloor heating by or buttons Confirm by button Thermostat is connected Go to the Smart Home app to configure it 9 Gateway has started flashing red and ...

Page 22: ...s Finish button to end the set up process in the app Choose More to expand the menu Select your thermostat and press Connect equipment button Name your thermostat and go Next Press gear icon 10 11 12 16 Choose No if you want to set your own schedule later or Yes if default now 13 Now choose Boiler Receiver If RX10RF is set as RX1 then choose option Boiler Receiver If as a RX2 then select Room Exte...

Page 23: ...browser 6 2 App icons description Menu view of HTRP RF 50 thermostat set as a programmable thermostat in SALUS SmartHome application Thermostat mode selection Thermostat Heat Cool mode indicator Setpoint temperature slider Thermostat name change tool Thermostat locking unlocking function Pin Unpin thermostat to from main application dashboard Additional thermostat settings including advanced insta...

Page 24: ...24 6 3 Change thermostat name pencil icon Name your termostat and confirm it by Save button Click on the pencil icon Select the thermostat in the main app menu 1 2 3 4 Press the thermostat s name ...

Page 25: ...rsor to left right on your App On your App screen the setpoint temperature is the number displayed in a larger font Select the thermostat in the main app menu 1 2 3 4 Old setpoint value New setpoint value Thermostat has started heating flame icon changed colour from white to orange ...

Page 26: ...ch is animating during cooling When thermostat is calling for heating then flame icon is displayed In the application you will see blue thermostat tile with snowflake icon when cooling mode is on 1 2 When there is jumper at CO terminal KL08RF is automatically working in cooling mode 3 1 2 3 When there is no jumper at CO terminal KL08RF is automatically working in heating mode In the application yo...

Page 27: ...u can choose to set the Default schedule that already exist in the App or to modify it according to your preferences The schedule is displayedatthebottomofscreenofyourAppontheselectedthermostat YoucanactivatetheschedulebypressingtheFollowScheduleicononyourApp Once activated the calendar icon will appear on your screen Choose Follow Schedule work mode 6 6Thermostat modes 6 6 1 Schedule mode To acti...

Page 28: ...N SUN Daily After days period selection use Add interval option to add your intervals to the schedule Then add a start time and temperature setpoint after all confirm by pressing Add button 4 5 6 TO SETTHE SCHEDULE INTHE APP Press thermostat s name Please note You can add as many intervals as you wish by repeating the procedure described from steps 3 to 6 The procedure is the same for all 3 schedu...

Page 29: ...LLY You can duplicate the same schedule for other thermostat s Click on the Duplicate schedule option Select thermostat for which you want to duplicate the schedule Now app is saving your choice and after it you will have the same schedule for thermostat s you ve selected Please note When thermostat has no schedule or it has been deleted then it maintains a constant temperature 21 C in Follow Sche...

Page 30: ... use Default schedule button It will remove all current intervals and it will set default schedule 4 Select thermostat in the main app menu 1 2 3 Scroll down and press pencil icon TO SET DEFAULT SCHEDULE Press thermostat s name ...

Page 31: ...ms that thermostat is in manual mode 1 2 2 6 6 2Temporary override mode Temporary override mode means manual temperature change during active schedule mode NOTE Temporary override mode will be maintained until next program will come as it has been set in the schedule When Follow schedule mode is active use slider to set new setpoint temperature When you have overwritten the temperature then hand i...

Page 32: ... please followe steps below Note When the thermostat exits frost protection mode previous mode will be restored PLEASE NOTE You can change frost protection mode temperature setpoint from the application level D08 parameter Follow steps below Press thermostat s work modes icon Click in the thermostat s name Select thermostat s settings Set frost setpoint temperature and confirm by Save button Selec...

Page 33: ...n lock unlock buttons in your thermostat by application When buttons are locked then also you can see on the thermostat display key icon Click on the padlock icon to lock unlock thermostat buttons 1 2 3 Click in the thermostat s name ...

Page 34: ...lose If you want to have acces to this function then first you have to add window door sensor OS600 or SW600 please refer to the OS600 or SW600 manual instruction To pair window door sensor OS600 SW600 with HTRP RF 50 thermostat please follow steps below Mark sensors which you want to link together with the thermostat You can additionaly lock buttons on thermostat when window is opened by marking ...

Page 35: ...there is no need to heat If you want to have acces to this function then first you have to add SPE600 Smart Plug to the SALUS SmartHome system please refer to the SPE600 manual instruction To pair SPE600 Smart Plug with HTRP RF 50 thermostat please follow steps below Choose plugs which you want to add to the thermostat Press Save button to finish pair process Choose the plug icon 1 2 Select the th...

Page 36: ...d to heat If you want to have acces to this function then first you have to add SR600 Smart Relay to the SALUS SmartHome system please refer to the SR600 manual instruction To pair SR600 Smart Relay with HTRP RF 50 thermostat please follow steps below Choose SR600 relays which you want to add to the thermostat Press Save button to finish pair process Press the relay icon 1 2 Select the thermostat ...

Page 37: ...ersal Gateway then we can easily identify which device is paired with which gateway In the Identification mode thermostat s display will start flashing Id information for 10 minutes You can also identify your device during thermostat s pairing process 4 Use the magnifying glass icon Click on the magnifying glass icon 1 2 Select the thermostat in the main app menu 3 Press thermostat s name ...

Page 38: ...in unpin thermostat from dashboard in Smart Home application please follow steps below 1 2 3 Open main menu in the app Select equipment Select All equipment option Select your HTRP RF 50 thermostat Press on the Pin icon to pin unpin thermostat to from the app dashboard 4 5 ...

Page 39: ...s basic settings Select the thermostat in the main app menu Select thermostat s settings 1 2 3 Press thermostat s name Select the hour format for the thermostat Set the frost protection setpoint temperature Turn on or turn off the display on the thermostat Installer administration settings BASIC SETTINGS 4 Scroll down to the settings section ...

Page 40: ...nly for qualified installers or knowledgeable users Scroll down to enter Admin settings Select the thermostat in the main app menu Select thermostat s settings 1 2 3 4 Press thermostat s name All service parameters with detailed admin settings are described on page 63 Please Note ...

Page 41: ...rs ComfortTemperature set thermostat temperature to 21 C Frost Protection Mode set thermostat to the Frost Mode temperature setpoint can be set in the user settings 5 C by default Holiday Mode set thermostat to the Holiday Mode To activate OneTouch rules please follow steps below example on Party Mode Party Mode has been activated You can check how it works by pressing Run now button Choose Party ...

Page 42: ...n example we will create OneTouch rule which activates send me a notification action under temperature is below 10 C condition Please look at the steps below how to set this OneTouch rule Press Add a AND OneTouch button Enter OneTouch rule name At this step choose condition which have to be fullfill in order to activate the rule ...

Page 43: ...mail or SMS notification and enter the message content Confirm by pressing Set button To finish OneTouch rule creation press Save button Choose the condition details for your thermostat In this case select Temperature Below option Enter a temperature setpoint trigger for your OneTouch rule Press Set button to confirm 7 10 11 12 8 9 ...

Page 44: ... pinned to the dashboard Newly created OneTouch rule tile can be found under OneTouch main menu and on your dashboard To force OneTouch rule activation select it tile 13 17 18 14 15 16 Please note SMS notifications will be send to the user only if they are activated in the OneTouch settings and UGE600 Universal Gateway is connected to the Internet ...

Page 45: ... 01 03 Floor Sensor Defect means that there is a break in the circuit of the temperature sensor plugged into the S1 S2 contacts of the thermostat or the sensor has been activated and not connected to the thermostat When problem has been solved sensor change or re connection in this case exclamation mark will disappear in application and thermostat will stop flashing error Full list of errors is in...

Page 46: ...ty is expressed in decibel units db Compare your value with scale below 50db to 0db very good quality signal 75db to 50db good quality signal 85db to 75db low quality signal 95db to 85db bad quality signal make wireless connection nearly impossible PLEASE NOTE Every Smart Home system device which is powered 230VAC is also working as a signal repeater of ZigBee network If system is based on battery...

Page 47: ...steps below NOTE FactoryresetfunctionremovesthermostatfromtheZigBeenetwork Thismeansthatthermostatisnotvisibleanymoreinthe Myequipment list At the very bottom of thermostat s menu choose Remove option Press Delete button to remove your thermostat from the app and confirm factory reset 1 2 Select the thermostat in the main app menu 3 4 Press thermostat s name ...

Page 48: ...ve your thermostat from the Zigbee network but you still will be able to see thermostat s tile After factory reset thermostat tile will change to dark grey colour 1 2 3 4 5 Wait few moments to finish factory reset procedure Now you can remove thermostat from the app Enter 47 code factory reset Hold buttons for 3 seconds to enter the installer mode Choose Factory Reset option Select del and confirm...

Page 49: ...LINEmodeusingtheUGE600UniversalGatewayandthenconnectedtotheInternet all devices should be found in the SALUS Smart Home application using Scan for equipment button All devices found in the application don t need to be reconfigured because all settings are automatically copied from the gateway Please note If your system was created using the CO10RF coordinator and you would like to control the devi...

Page 50: ...ik modułu sterowania pompy w listwie KL08NSB jest beznapięciowy dlatego podłączając pompę CO należy wykorzystać zewnętrzne źródło zasilania pompy N L UWAGA Przekaźnik modułu sterowania pompy w listwie KL08RF jest beznapięciowy dlatego podłączając pompę CO należy wykorzystać zewnętrzne źródło zasilania pompy astosowania regulatorów temperatury 8RF można podłączyć poniższe regulatory egulator podtyn...

Page 51: ...kowy czarny zasilany 230V VS20WRF Regulator natynkowy biały zasilany bateryjnie 4xAAA VS20BRF Regulator natynkowy czarny zasilany bateryjnie 4xAAA Powyższe regulatory mogą być stosowane wymiennie w różnych strefach Uwaga Każde urządzenie w serii iT600RF zasilane napięciem 230V jest jednocześnie repeater em sygnału zwiększa zasięg sieci regulatorów GRUPA 2 Regulator programowany VS10WRF Master gr 1...

Page 52: ...rogramowany VS20WRF Maste gr 2 zasilany bateryjnie GRUPA 1 Regulator indywidualnej strefy grzewczej Zasilanie 230V AC Przewód 1 5mm2 Dostarcza instalator V AC Rozdzielacz ogrzewania podłogowego Moduł sterowania kotłem listwy KL08RF należy podpiąć do kotła w miejsce zworki termostatu pokojowego N L N L Wyjście na czujnik punktu rosy opcjonalnie UWAGA Przekaźnik modułu sterowania pompy w listwie KL0...

Page 53: ...buttontoconfirm 4 Now thermostat is looking for the signal from the coordinator 3 Set your thermostat for underfloor heating by or buttons Confirm by button In this chapter you will learn how to set HTRP RF 50 thermostat as a group controller MASTER Please look at the instructions below HTRP RF 50 AS A GROUP CONTROLLER MASTER 7 2 2 Grouping installation of the thermostat as a group controller MAST...

Page 54: ... coordinator When thermostat is succesfully paired main screen will be displayed PLEASE NOTE For easier installation please make sure you have already added Underfloor HeatingWiring Centre Control Box KL08RF to your ZigBee network please refer to the wiring centre manual instruction Set your thermostat for underfloor heating by or buttons Confirm by button 3 OpentheZigBeenetwork OR 5sec 5sec Use o...

Page 55: ...is occupied by other thermostat it will remove it from that zone To do it follow steps below 1 2 3 Press button to confirm zone replacement You can always change the zone using or buttons if you don t want to replace it Confirm by button When thermostat is succesfully paired main screen will be displayed 3 ...

Page 56: ...or head manual instruction 1 4 7 8 9 2 Set your thermostat for radiators by or buttons Confirm by button 3 OpentheZigBeenetwork OR 5sec 5sec Thermostat is searching forTRVs radiator heads 5 6 Holdthebutton for10seconds TheLEDontheheadshouldstart toblinkred You can pair up to 6TRV s with 1 thermostat AllTRV s have to be within the same room with thermostat 10sec Deviceispairedwithcoordinator diodeo...

Page 57: ...57 11 10 12 Close the ZigBee network OR 3 3 5sec 5sec When thermostat is succesfully paired main screen will be displayed TRVhasbeenadded ...

Page 58: ...e make sure you have already added RX10RF receiver to your ZigBee network please refer to the RX10RF receiver manual instruction 2 3 Now thermostat is looking for the signal from the coordinator 4 OpentheZigBeenetwork OR 5sec 5sec 8 Close the ZigBee network OR 3 3 5sec 5sec 7 When thermostat is succesfully paired main screen will be displayed 1 Hold buttons for 3 seconds to launch the extended con...

Page 59: ...thermostat works in the cooling system Acting alone works as a manual mode Standardtemperaturemode pre definedsetpointtemperature Usuallysetduringthedaywhenwearearoundthehouse Actingaloneworks as a manual mode Economic temperature mode pre defined setpoint temperature Usually set at night or when we are out of the house Acting alone works as a manual mode Automatic mode temperature schedule follow...

Page 60: ...ing centre Look at the instructions below When thermostat is calling for cooling then snowflake icon is displayed When thermostat is calling for heating then flame icon is displayed 1 CO terminal of the KL08RF wiring centre if contacts are closed then all thermostats paired with KL08RF are in cooling mode 2 1 2 CO terminal of the KL08RF wiring centre if contacts are opened then all thermostats pai...

Page 61: ... below There are 4 possible schedule variants Use and buttons to select schedule variant and confirm by button Separate schedule for WORKING DAYS Separate schedule for WEEKENDS One schedule for WHOLEWEEK Seven separate schedules for SINGLE DAYS 1 2 3 Enter into the schedule settings Hold button for 3 seconds to enter the menu 3 sec ...

Page 62: ...ograms time periods in the schedule Hold button for 3 seconds to save and exit schedule editing To run the schedule activate thermostat s automatic mode use and buttons to move the frame to the A icon Schedule programming example for theWORKING DAYS variant 10 4 5 6 8 9 7 Use and buttons to choose comfort standard or economic setpoint temperature Schedule editing will jump to the next program s ti...

Page 63: ...h using and buttons Confirm by button Set year using and buttons Confirm by button Set minutes using and buttons Confirm by button Set day using and buttons Confirm by button 3 DATE settings will automatically appear after clock setup Hold button for 3 seconds to enter the menu Go to the time and date settings using and buttons Choose time and date settings option by button First select time forma...

Page 64: ...ibrate thermostat s temperature sensor please follow steps below 1 4 7 6 Set temperature calibration value using and buttons To increase decrease value use and buttons Go to the thermostat calibration settings using and buttons Move forward using button 5 2 3 8 Hold button for 3 seconds to enter the menu Confirm by button Confirm by button Thermostat will go back to the main screen after saving th...

Page 65: ...s displaying 8 3 4 Key lock function To LOCK UNLOCK HTRP RF 50 thermostat keys in OFFLINE MODE you have to press and hold buttons for 3 SECONDS When thermostat is locked you will see key icon on the display When thermostat is unlocked padlock icon is not visible 1 2 3 3 sec 3 sec ...

Page 66: ... button 4 2 Hold buttons for 3 seconds to enter the installer mode dXX Function Parameter Values Description Default Values d00 Temperature unit 0 Celsius C 0 1 Fahrenheit F d01 The method of controlling the temperature of the heating system 0 byTPI algorithm 0 1 SPAN 0 5 C 2 SPAN 1 0 C d02 Correction of the displayed temperature from 3 0 C to 3 0 C If the thermostat indicates an incorrect tempera...

Page 67: ...ure that can be set by the user 35 C d13 Cooling temperature limit 5 40 C Minimum heating cooling temperature that can be set by the user 5 C d14 Max floor temperature active in heating mode when d04 1 6 45 C To protect the floor against overheating the heating will be switched off when the maximum temperature of the floor sensor is reached 27 C d15 Min floor temperature active in heating mode whe...

Page 68: ... Factory Reset To RESET HTRP RF 50 thermostat to it s factory default settings please follow steps below 1 2 3 4 5 Wait few moments to finish factory reset procedure Use or buttons to choose code 47 Press button to confirm Select del and confirm choice by pressing button 3 ...

Page 69: ...orted Check floor sensor wire insulation for any damages Sensor resistance for 25 C 10kΩ 5 Err XX 05 Thermostat lost contact with the CO10RF network coordinator or the UGE600 internet gateway Check the coordinator gateway power supply connection Force identification process from the coordinator gateway or thermostat 6 Err XX 06 Thermostat lost connection with the wiring centre Is the wiring centre...

Page 70: ...e devices are within the network Send the heating signal from thermostat If the top LED diode is flashing perform the pairing procedure according to the RX10RF manual instruction 11 18 Err XX 11 XX 18 Wiring centre has lost connection with thermostat of the given zone e g 11 with zone 1 12 with the zone 2 etc Error is displayed on all thermostats Check the thermostat power supply Send the heating ...

Page 71: ... SALUSTechnical Department 31 Err XX 31 Adaptation error of theTRV head assembled on the radiator valve insert Check assembly of theTRV head on radiator valve insert and reinstall theTRV head Check the compatibility of theTRV head and radiator valve insert replace the valve insert if necessary 32 Err XX 32 Thermostat s battery level is low Replace thermostat batteries 33 Err XX 33 The RX10RF recei...

Page 72: ...ermostat requires no special maintenance Periodically the outer casing can be wiped clean using a dry cloth please DO NOT use solvents polishes detergentsorabrasivecleaners asthesecandamagethethermostat Therearenouserserviceablepartswithintheunit anyservicing or repairs could only be carried out by Salus Controls or their appointed agents 12 Cleaning and Maintenance 13 Technical Informations 85 mm...

Page 73: ...ctwillbefreefromanydefectinmaterialsorworkmanship andshallperforminaccordancewithitsspecification foraperiodoffiveyearsfromthedateofinstallation SALUSControlssoleliabilityforbreachofthiswarrantywillbe atitsoption torepairorreplacethe defective product ...

Page 74: ...L CONTROLS Sp z o o Sp k Rolna 4 43 262 Kobielice Poland www salus controls com SALUS Controls is a member of the Computime Group Maintaining a policy of continuous product development SALUS Controls plc reserve the right to change specification design and materials of products listed in this brochure without prior notice Issued 10 VII 2020 Version 6 ...