15.

 

TROUBLESHOOTING 

Symptom 

Remedy 

Controller is not working 

1.

 

Start the controller by keeping its knob depressed for at least 

2 seconds 
2.

 

Check power supply 

3.

 

Check fuse in the controller 

Controller 

alarms 

on 

collector 

overheating 

1.

 

Collector pump runs at too low speed 

2.

 

Collector  pump  capacity  is  too  low,  pump  is  not  able  to 

transfer heat to reservoir exchanger 
3.

 

Temperature  preset  for  reservoir  has  been  reached  and 

controller has disabled the pump. Collector pump is switched on 
by  collector’s  critical  temperature;  relevant  laud  alarm  may  be 
set off in options.  

 
 

Record of changes 

First edition  
Rev. 1.1 z of 20-04-2012  

1.

 

Update of unit current 

 

 

The  manufacturer  reserves  the  right  to 
make  changes  in  design  and  software 
without prior notice 

 

Summary of Contents for PCSol 150

Page 1: ...Controller PCSol 150 REVISION 1 1 SOFTWARE 1 xx 26 05 2015 FOR SOLAR COLLECTORS INSTALLATION AND OPERATION MANUAL...

Page 2: ......

Page 3: ...diagram of connections 16 12 1 1 Use of connectors 17 12 1 2 Power supply connection 17 12 1 3 Temperature sensor connection 17 13 HOW TO CLOSE CASING 18 14 FUSE REPLACEMENT 19 15 TROUBLESHOOTING 20 L...

Page 4: ...c system to which the controller is connected must be protected with a cut out device suitable for expected loads Never use the controller when its casing is damaged In any case do not alter the contr...

Page 5: ...and electronic products disposal system It is recommended to process in accordance with local regulations and not to dispose used products to household garbage containers Proper disposal of outdated...

Page 6: ...6...

Page 7: ...OPERATING MANUAL PCSol 150...

Page 8: ...long with the temperature rise Measured temperature is shown with the step of 10 C for T1 sensor collector s temperature and 5 C for T2 sensor DHW reservoir temperature Subsequent segments of the indi...

Page 9: ...llector temperature TCOLmin move the cursor to the indicator with sun symbol Press the knob sun symbol will start fast blinking to enter value editing mode You may change the value by turning the knob...

Page 10: ...ted by illumination of the sun symbol indicator When the collector temperature drops two degrees below minimal temperature preset the sun symbol will go off and the controller will disable the collect...

Page 11: ...n interruption Alarm on incorrect operation or damage to T2 sensor Signals interruption in T2 sensor circuit Check if the sensor is not e g off the unit or the connecting wire is cut Collector pump op...

Page 12: ...roller off the pump operation will be stopped 9 1 Test of unit When switched on the unit undergoes some testing At the time the display shows alternately the testing screen and the software version Te...

Page 13: ...INSTALLATION MANUAL PCSol 150...

Page 14: ...the set Controller PCSol 150 Temperature sensor T1 CT6w Temperature sensor T2 CT6 Installation and operating manual 1 pc 1 pc 1 pc 1 pc 11 INSTALLATION The controller is designed for operation in the...

Page 15: ...ust and water access is prevented Permissible operating temperature is not exceeded 40 C for controller Air exchange inside casing is allowed Access to dangerous parts is disabled Electrical installat...

Page 16: ...in sections 12 1 2 12 1 3 Presented hydraulic diagram will not replace central heating technical design and may be used only for informative purposes Collector and hot water reservoir must be install...

Page 17: ...act surfaces with temperatures that exceed the cables operating temperature limits The controller has no PE protective connector because the controller itself does not require grounding PE terminals o...

Page 18: ...r must be located in thermometric tube between the supply and return connectors of the collector exchanger pipe coil The sensors resistance per temperature table CT6w CT6 Temp C Min Nom Max 0 999 7 10...

Page 19: ...t means that the fuse is burnt and must be replaced For the unit use sub miniature slow blow fuse 1 25A compliant to IEC 60127 and with maximum switching current not lower than 100A Example of such fu...

Page 20: ...Collector pump capacity is too low pump is not able to transfer heat to reservoir exchanger 3 Temperature preset for reservoir has been reached and controller has disabled the pump Collector pump is...

Page 21: ...Presented drawing is in 1 1 scale and it may be helpful during installation You may cut off this page and use to mark installation place Fig 15 1 Casing drawing for installation aid...

Page 22: ......

Page 23: ......

Page 24: ...SALUS Controls Made in Poland...

Reviews: