TEST / PAIRING
SELECT
+Hr
SET
i
Once paired please close the
boiler control panel.
The LED will start flashing red.
i
When enter test pairing
mode, after a 10 minute
countdown the thermostat
will time out.
+Hr
Quick Guide
RT510LG5V
Always isolate the AC Mains supply before installing or working on any components
that require 230 VAC 50Hz supply.
RT510TX Button Functions
TEST / PAIRING
SELECT
+Hr
SET
TEST / PAIRING
SELECT
+Hr
SET
3 Sec
TEST / PAIRING
+Hr
SELECT
SET
TEST / PAIRING
SELECT
SET
LG+5V Installation
Introduction
The RT510TX thermostat will switch your heating system on or off, as needed, in accordance
with the time and temperature set by you. It can be used with the LG+5V integral plug-in
RF boiler module. The LG+5V boiler module 868MHz is a receiver with 5V DC to control ON/OFF of
Boiler or other heat system via the RF signal transmitted from the thermostat.
868.0-868.6MHz; <13dBm
Safety Information
Use in accordance with the regulations. Indoor use only. Keep your device completely dry. Disconnect
your device before cleaning it with a dry cloth. This accessory must be fitted by a competent person, and
installation must comply with the guidance, standards and regulations applicable to the city, country or
state where the product is installed. Failure to comply with the relevant standards could lead to prosecution.
Product Compliance
This product complies with the essential requirements and other relevant provisions of the following EU Directives: EMC
2014/30/EU, LVD 2014/35/EU, RED 2014/53/EU and RoHS 2011/65/EU. Full text of the EU Declaration of Conformity is
available on www.saluslegal.com
3
4
+Hr
SELECT
SELECT
SET
SET
+
+
+
Key
Function
1. Press once to activate Frost Mode
2. Press for 3 seconds in order to activate Holiday Mode
Press once to activate/deactivate Boost function
Press once to enter/exit Permanent Override function
Increase button
Decrease button
Select the clock or programme settings
Press to confirm your settings
1. Press once to enter/exit in Test Mode
2. Press for 3 seconds to enter/exit Pairing Mode
Press the buttons for 3 seconds to enter Installer Mode
Press the buttons for 3 seconds to enter Clock Settings
Test the Pairing Process
LG+5V Switch Position
Box content
Pairing Process
Once the LED stops flashing, press the
TEST / PAIRING button for 3 sec.
The boiler receiver is
OFF
.
When in this
mode, the boiler will not receive a signal
from the RF thermostat.
AUTO
.
RX will automatically receive the RF
signal from your compatible SALUS device
and control the module output so that it
switches the boiler accordingly.
MANUAL
mode - Manual Override. When in
this mode, the boiler will be always turned
on and the LED indicator will also be lit
constantly.
1
1
1
4
1
2
2
2
5
2
3
3
3
6
7
Press the SYNC button for 3
seconds until LED starts flashing.
3 Sec
The LG+5V is ready to be paired
with your thermostat.
Connect the electrical plug.
The LG+5V is ready to be paired with your
thermostat.
Push fit boiler control into housing.
Reverse the procedure to install the
LG+5V.
Pull down control panel cover.
Remove existing mechanical timer /
blanking plate and unscrew from plate.
Ensure boiler is isolated and switched off.
Mechanical
Timer
Blanking
Plate
LG+5V User Controls
LED
-
It will be on when the thermostat is demanding
heat.
Mode Switch
ON – Boiler will be on continuous
AUTO – will follow time and temperature program in
the transmitter
OFF – Boiler is off
SYNC Button
-
This is used only for pairing the RF
communications.
Quick Guide
2 x AA Alkaline
Batteries
2 x Fixing Screws
RT510TX
LG+5V
Desk Stand
Begin the pairing process
End the pairing process
i
i
When removing blanking plate, also remove visible thermostat link plug, do not remove
any internal link.
During test pairing, boiler control should flash confirming pair. If not, please follow
Pairing Process.
RT510TX Dip Switch Settings
The DIP Switches can be found on the rear of your thermostat.
Control feature
TPI
Span
Operation
When TPI is selected on DIP
switch № 2, the DIP switch
№ 1 is functional. You can
choose the Cycles Per Hour
between a lower comfort
level (6CPH) and a higher
comfort level (9CPH).
When Span is selected
on DIP switch № 2,
the DIP switch № 1 is
not functional. The
temperature accuracy of
your thermostat is set to
± 0.25 °C.
TEST / PAIRING
SELECT
+Hr
SET
3 Sec
SALUS C
ontrols is a member of the C
omputime Group
.
Maintaining a polic
y of continuous produc
t development SAL
US Contr
ols plc reser
ve the r
ight to
change specification, design and mat
erials of pr
oducts list
ed in this brochur
e without prior notic
e.
Issue Date: F
ebruary 2018
V014
For PDF I
nstallation guide please go t
o ww
w.salus-manuals
.com
SALUS C
ontrols plc
SALUS House
Dodw
orth Business P
ark S
outh,
Whinby R
oad, D
odwor
th,
Barnsle
y S75 3SP , UK
.
T: +44 (0) 1226 323961
E: sales@salus-tech.com
E: techsuppor
t@salus-tech.com
ww
w.salus-t
ech.com