Preventative Maintenance Manual – Salute RDX
2020/12/07
2
Disconnect the wiring from the timer.
d) Use a needle-nose plier to remove the pin by pressing the valve. Remove round
valve and spring. Separately wipe and clean the upper and lower valve.
e) Grease (use an inert grease such as lithium grease) and replace or assemble
components in the reverse order of removal. Blue wiring is on the top. When
replacing tubing please see diagram below and connect outlet tube A to valve port 1,
outlet tube B to valve port 2, etc. A
、
B is 6 cm tubing. D
、
E is 7cm tubing.
C
、
F is 8cm tubing.
1
2
3
4
5
6
A
B
C
D
E
F