Installation instructions
22 / 28
8.7.2
Check flow pressure, output pressure
These work activities may be performed only by an
experienced representative of the manufacturer or
the installer of the gas supply utility.
The pressure meter must have a measuring accu
racy of 0.1 mbar/10 Pascal.
Checking the flow pressure
.
Shut the gas shut-off device.
.
Release the screw on the “flow pressure”
pressure measuring socket.
.
Connect the pressure meter to the “flow
pressure” pressure meter.
.
Open the gas shut-off device.
.
Switch on the appliance.
Filling the gas supply line
.
Start the cooking process
D
The gas burner starts and ignites automatically.
D
The ignition attempt is made three times if the gas mixture is not yet ready to ignite. The appliance will
switch to the fault mode after three ignition attempts. The device must be restarted by shutting if off and
on again.
D
Depending on the length of the gas supply line, the ignition attempts may need to be repeated several
times until the gas supply line has completely filled with gas.
D
Repeat this process until the gas line is filled and the gas burner therefore ignites without faults.
Depending on the length of the gas supply line, this on and off-switching process must be repeated up
to 10 times.
Measuring the flow pressure
.
Measure the flow pressure.
.
Check the values with data in the table, page 20 chapter 8.3 for agreement.
D
If the gas pressure is lower than the required pressure for the type of gas, the gas supply utility must be
contacted. The integrated gas control valve automatically reduces excess flow pressure.
.
Switch off the appliance.
.
Shut the gas shut-off device.
.
Remove the pressure meter.
.
Turn down the screw on the pressure measuring socket against the stop (sealing tightly).
Pressure measuring socket “flow
pressure/connection pressure” with
screw (socket diameter approx. 9 mm).
Gas control
valve