Installation instructions
23 / 28
Measuring the output pressure
.
Release the screw on the “output pressure”
pressure measuring socket.
.
Connect the pressure meter to the “output
pressure” pressure meter.
.
Open the gas shut-off device.
.
Switch on the appliance.
.
Start the cooking process.
.
Measure the output pressure.
D
The output pressure must be -0.1 mbar
±0.02 mbar / -10 Pascal ±2 Pascal. If the output
pressure does not lie within this range, it must be
adjusted.
Adjusting the output pressure
.
Remove the closing screw.
.
Make the adjustment with the Torx screwdriver/bit
(T40).
D
Use a non-magnetic Torx screwdriver/bit if possi
ble.
−
Turning counterclockwise reduces the output
pressure.
−
Turning clockwise increases the output
pressure.
.
Screw down the closing screw after the adjust
ment of the output pressure.
.
Switch off the appliance.
Close the appliance
.
Attach the side wall of the appliance.
8.8
Exhaust gas analysis/setting exhaust gas values (CO
2
)
Exhaust gas values, see table page 20 in chapter 8.3
For setting exhaust gas values, please see service manual!
Gas control valve
“Output pressure” pressure measuring
socket
Closing screw (Torx size T40)
Adjusting screw (Torx T40)
Adjusting screw setting