Installation instructions
14 / 28
4.3
Connection of soft- and cold water
Risk of damage
The appliance may not be operated without water connection! A water connection is re
quired even if the appliance is only used for baking!
D
The connection requires using a pressure-resis
tant flexible DVGW/SVGW-tested hose with a
diameter of at least 1/2inch and union of 3/4 inch.
Provide a hose of adequate length to allow the
appliance to be moved during service tasks.
D
The appliance are factory-equipped with a soft-
and cold water connection. Use the connecting
piece only if you cannot provide separate water
supplies and the specifications for the cold and
soft-water connections are ensured.
.
Rinse through the water pipes in the building sys
tem and supply hoses before connecting.
.
According to SVGW: Install a backflow guard be
tween water tap and supply hose, provided by the
customer and easily accessible.
.
Connect the appliance to an easily accessible
water stopcock.
D
The supply hose may not be kinked or deformed!
.
Check that all connections are watertight.
Connection with connecting piece
The connecting piece may be used only if the water
corresponds to the requirements for soft water.
For requirements on the cold- and soft water connec
tion, see page 13 Chapter 4.2.4
611/621, 1011/1021, 2011/2021 QT
Soft water connection
Cold water connection
Dirt screen item No.:
249688 (factory-in
stalled)
Connection piece item
No.: 878801 (cannot be
used for type T )
Water connection
G3/4 inches
Sealing ring (included in
connecting piece)
Check valve item No.:
879082 (factory-in
stalled)
Backflow guard / backflow pre
venter item no.: 886240
Summary of Contents for Cucina Evo Easy Series
Page 27: ...27 28 ...