en
46 / 48
Check the gas connection pressure
.
Close the customer gas tap.
.
Loosen the screw plug in the connection nipple
with a screwdriver.
.
Connect the gauge to the connection nipple.
.
Open the customer gas tap.
.
Ignite the gas burner.
.
Check that the main flame is burning.
.
Read the gas connection pressure.
.
Check to see whether the pressure is not less than the minimum or has not exceeded the maxi
mum - gas pressures, refer to the table on Page 38 Chapter 9.1.1.
−
If the pressure is too high: Install a pressure limiter.
−
If the pressure is too low: Check the house installation / inform the gas supply company.
−
Do not set and start up the appliance, if the gas-primary pressures have been exceeded or
fallen short of!
After connection and pressure check
.
Close the connection nipple with the screw plug.
.
Check all gas-bearing parts for tightness (leak spray).
.
Screw front cover down securely.
.
Connect the clamping cam.
11.
Service
● Have an annual inspection and maintenance carried out on the appliance. Maintenance tasks
include: safety, function and leak testing.
● The safety equipment should be inspected by a technical expert at least once a year, to ensure
that it is in proper condition.
● Installation, service and repair tasks must only be carried out by gas specialists.
● Use only genuine accessories and spare parts.
● We recommend negotiating a service contract with Customer Service.
Connection nipple
Hose
Pressure gauge
Screwdriver