SAM4s ER-900 Series Operator's & Programming Manual v.1.3
Introduction • 19
Initial Clear
CAUTION: Do not share this information with unauthorized users. Distribute the
PGM Mode key only to those you may want to perform this function.
The initial clear function allows you to exit any register activity and return to a beginning or
cleared state. Any transaction that is in progress will be exited and totals for that transaction
will not be updated.
Here are some reasons you may want to perform an initial clear:
The register is in an unknown state, and you wish to exit the current program or
transaction without following normal procedures.
You have performed a function that includes a compulsory activity and you wish to
bypass the compulsion.
An initial clear may be necessary as part of servicing, or troubleshooting.
Perform this procedure only as necessary. Contact your SAM4s dealer first if you have
questions about operating or programming your SAM4s ER-900.
To Perform an Initial Clear:
1.
Turn the power switch located on the right side of the register to the
OFF
position.
2.
Turn the control lock to the
PGM
position.
3.
For Flat Keyboard Models (ER-920/ER-940):
Press and hold the key position where the
CHECK
key is located on the default
keyboard layout.
For Raised Keyboard Models (ER-925/ER-945):
Press and hold the key position where the
SUBTL
key is located on the default
keyboard layout.
4.
While continuing to hold the appropriate key, turn the power switch to the
ON
position.
5.
The message "INITIAL CLEAR OK!” prints when the initial clear is complete.
Summary of Contents for ER-900 Series
Page 10: ...10 Introduction SAM4s ER 900 Operator s Programming Manual prelim ...
Page 20: ...20 Introduction SAM4s ER 900 Series Operator s Programming Manual v 1 3 ...
Page 34: ...34 Getting Started SAM4s ER 900 Series Operator s Programming Manual v 1 3 ...
Page 116: ...116 S Mode Programming SAM4s ER 900 Series Operator s Programming Manual v 1 3 ...