Sam4s SPS-300 OP Manual v1.35
Z Mode • 111
When a report is selected, the
Z REPORT OPTIONS
screen displays:
Z REPORT OPTIONS
RPT# : FINANCIAL
1. TYPE 0
0:DAILY 1:PERIOD
2. 0:PRINT 0
3. IRC 0
0:STANDALONE
1:ALL 2:SELECT
Select the
TYPE
(DAILY or PERIOD) and the
IRC
configuration. Refer to the
explanations in the table below. Press
CASH
after each selection. After the last
selection, the report will start.
If you chose
IRC 2 : SELECT
, then the register selection displays:
Z REPORT OPTIONS
RPT# : FINANCIAL
1. TYPE : 0
0:DAILY 1:PERIOD
2. 0:PRINT 0
3. IRC 2
0:STANDALONE
# 1Y
2N 3N 4N 5N 6N 7N 8N
Press the
YES/NO
key at each register # to select whether you wish to include each
register in the consolidated report. Press
CASH
after each selection. After the last
selection, the report will start.
Field
Description
TYPE
Select Z1 or Z2 if available for the selected report.
IRC
Select STANDALONE, ALL, or SELECT if available
for the selected report. If SELECT, the screen prompts
for selection of registers - the screen will initially show
the registers available from the from/to IRC register
programming, for example if the IRC range is from 1
to 3, then the selection will default to:
1Y 2N 3N 4N 5N 6N 7N 8N