Not Found PLU
Note: The System Option “DISABLE NOT FOUND PLU” must be set to N(o) to allow this
function.
The “Not Found PLU” feature is available for use when an optional scanner is used to input
PLU’s. If an item is scanned that is not programmed in the PLU file, the operator has the option
to input the price of the item and assign it the same descriptor and properties of another PLU, or
enter the descriptor and tax status independently. This provides a simple mechanism for quickly
building an item file for a simple scanning installation. (Note: Beginning at version 1.043, the
error sound continually when a not found PLU is attempted.)
Quick Entry Method
Scan an item or input a
PLU
number. If the item is in the PLU file, it will register, if
an item is not in the PLU file, an error will sound continually.
Press
CLEAR
, the
NOT FOUND PLU
screen will display:
NOT FOUND PLU PROGRAM ?
0 : NO 1 : YES
Press the numeric
“1”
key to allow the registration of the PLU. The cursor will point
at the
SELECT COPY PLU
field.
NOT FOUND PLU PROGRAM ?
SELECT COPY PLU
0
PRICE: 0