55
OPERATOR’S MANUAL
REAR EXTENSION ARMS
KWT, CAMEL, KOLIBER, KW, LAMA
6.6.
Manual control of electrical and electrical-proportional distributor
In case of electrical and electrical-proportional control failure it is possible to adjust the
hydraulic distributor manually. This allows for mechanical machine folding and emergency service
drive. Please learn the below description of procedure for two types of distributors:
a)
Electrical E control
In case of electrical E-control there are two types of hydraulic distributors: type I (
) and type
II (
).
To overload hydraulic distributor type I with electrical control (
):
❑
push the button (
6
) and turn it left,
❑
next adjust hydraulic actuators by pushing buttons (
1
), (
2
), (
3
) on solenoid valves under hydraulic
hoses,
❑
to change sections (
4
) and (
5
) firstly apply 12V voltage on the solenoid valves and then adjust in
the same manner as in the case of other.
❑
unscrew button (
6
) to its primary position.
Fig. 63a.
Hydraulic distributor E type I
–
description of distributor functions:
1-
1- turntable, 2- arm extension, 3- 2nd extension arm, 4- main extension arm,
5- cutting part, 6- start distributor
To overload hydraulic distributor type I with electrical control II (
):
❑
loosen jam nut and drive bolt (
6
) to the end,
❑
next adjust hydraulic actuators by pushing buttons (
1
), (
2
), (
3
) on solenoid valves under hydraulic
hoses,
❑
setting sections (
4
) and (
5
)
–
unscrew buttons from the solenoid valves, then press and hold every
solenoid button and reset hydraulic cylinders,
❑
drive all buttons to their primary position,
❑
unscrew button (
6
) to the end and lock jam nut.
6
1
2 3
4 5