Operator's manual
Arm
Flail head
- 39 -
II.
Control panel with electrical controlling
Controlling KOLIBER E extension arms and operating head is possible thanks to lever (I) as
well as (J) control panel Fig. 43, marked with corresponding labels:
E – power on/off;
F – hydraulic engine (22) on/off;
- position „0” - turning hydraulic engine off;
- position „I” - turning hydraulic engine on;
- position „II” – once switch is in position „II” hydraulic engine is being turned on and
opposite rears are possible to be turned on earlier than during operation by means of switch
„G”;
G – hydraulic engine turn on/off – rears opposite to operation, used for cleaning the shaft from
wound up material. Opposite engine rears can be turned on only upon pushing „F” to
position „II”;
H - floating function for operating head on/off:
ON – turning floating function for operating head on,
OFF – turning floating function for operating head on (controlling operating head by
means of cylinder (4) with lever I),
I – controlling extension arms – external cylinder (1) and internal cylinder (2) of the lifting
device,
J – controlling operating head.
Fig. 43. Control panel with electrical option (applies to: Koliber 400E/450E)
4
1
14
23
2
E
I
J
F
G
H