Discussion & Voting Conference & Video Auto Tracking

 

8.2.1.

 

Function Description 

„

 

Implement discussion and 

voting

 function. 

„

 

Control the conference by setting the limitation of active microphones and active mode from the control 
host or software in console PC. 

„

 

Addresser’s voice will be transferred to the build-in loudspeaker of each contribution unit. 

1

 

Need to input some background music and output the audio to amplifier and recorder. 

8.2.2.

 

System Configuration 

„

 

SCS-6100MA     SCS control host 

„

 

SCS-6190C    

SCS chairman unit 

„

 

SCS-6190D    

SCS delegate units 

„

 

Software package (optional) 

„

 

SCS-690HD            SCS high speed dome camera 

„

 

CBL CABLE      SCS cable 

…

 

SCS-E1       

Single earphone 

…

 

PC                    

Console PC 

…

 

PA                     

Amplifier 

…

 

DVD         

DVD player 

CASSETTE     Recorder

 

 

 

 

 

8.2.3.

 

System connection 

 

 

 

 
 

Summary of Contents for SCS-350MA

Page 1: ...Conference System User Manual SAMCEN i SAMCEN Professional Audio Conference System Fully Digital Congress System Please read the instruction carefully before using User Manual...

Page 2: ...VC D SCS 6150C D SCS 6170C D SCS 6190C D SCS 350MA SCS 350TA SCS 360RA etc It is only an instruction for operators not for any maintenance usage This manual is copyright SAMCEN Corporation China All r...

Page 3: ...oid any damage by over heat please keep the working environment good in ventilation to radiate the heat when running the machine The machine should be turned off when in rainy and humid days or nonuse...

Page 4: ...it 16 2 8 SCS 6001C D discussion unit 17 2 9 SCS 6190C D voting system unit 18 2 10 SCS 6170C D voting system unit 19 2 11 SCS 6150C D voting system unit 20 3 SCS Simultaneous Interpreter Unit 20 4 SC...

Page 5: ...aration Just for voting system 34 7 5 Start meeting just for voting system 34 7 6 Report 36 7 7 Assistant 36 7 8 End meeting 36 7 9 Software update notification 36 8 SCS Engineering Examples 36 8 1 Ba...

Page 6: ...ay the more clearly we get z The contribution equipment adopts condenser microphone with unidirectional response z The contribution equipment adopts built in hi fi loudspeaker z The lightweight earpho...

Page 7: ...CS 6001D Delegate unit flush mount design SCS Fully Digital Voting System Unit SCS 6190C Chairman voting unit with LCD display SCS 6190D Delegate voting unit with LCD display SCS 6170C Chairman voting...

Page 8: ...th the Telephone Interface it can open a telephone conference with remote user 10 Support voting and its data managing 11 Cover with metal material and earth well to ensure the 8000V antistatic perfor...

Page 9: ...N LEFT and RIGHT to switch from term to term uses the up down button and uses these four buttons to move the camera in setting preset ENTER enter confirm button setting and switching the modes with th...

Page 10: ...opened automatically The green light of waiting microphone will twinkle In order to reach the purpose of restrict on the number of speakers Auto Meeting Mode you can set the number of talkers for 1 6...

Page 11: ...ower by the controller operating voltage of DC 24V meet safety standards z Equipping with AC and DC dual channel safety devices z Built in auto alarm function when the electricity instability error or...

Page 12: ...the same time In this mode it allows three talkers to line up when the talking microphone is closed the first lining up will be opened automatically The green light of waiting microphone will twinkle...

Page 13: ...ker mutes automatically and the delegate can speak z Press the Mic On Off button again to turn the microphone off The speaking indicating lamp ring turns off The built in speaker is turned back to the...

Page 14: ...g indicating light will blink press this key to abstain 4 Key4 Candidate 4 Response z In voting elect 1 5 mode voting indicating light will blink red and green press this key to vote for candidate 4 z...

Page 15: ...ores key4 75 scores key5 100 scores 1 Key1 check the voice control and sensitivity Key2 check the edition of the microphone Key3 check unit s ID number 2 Press key1 and key4 in the same time decrease...

Page 16: ...A control host to expand the contribution units in system 2 Input voltage between 100 240V it can endure 3500V high voltage 3 Cover with metal material and earth well to ensure the 8000V antistatic pe...

Page 17: ...rman unit Desktop SCS 6050D Delegate unit Desktop SCS 6040C Chairman unit Desktop SCS 6040D Delegate unit Desktop SCS 6010VC Chairman unit Desktop SCS 6010VD Delegate unit Desktop SCS 6001C Chairman u...

Page 18: ...itch of chairman unit Controlled or limit the unit 2 5 2 Feature 1 Novel appearance design and exquisite technical process enable the cabinet rank in the first line of international superior conferenc...

Page 19: ...er will be cut off when turn on the microphone or connect the headphone 10 Microphone unit indicator double LED in red the microphone can be used if in green the microphone is limited 11 ON OFF button...

Page 20: ...he best result 9 Built in amplifier the amplifier will be cut off when turn on the microphone or connect the headphone 10 Microphone unit indicator double LED in red the microphone can be used if in g...

Page 21: ...he unit 2 8 2 Features 1 Excellent metal wiredrawing craft classic in black and streamlined faceplate 2 Small in size low in weight solid in quality economical and practical convenient to transport 3...

Page 22: ...used if in green the microphone is limited 11 ON OFF button chairman has the priority 12 The first in switch of chairman unit controlled or limit the unit 13 Five buttons on the voting machine 1 YES...

Page 23: ...he amplifier will be cut off when turn on the microphone or connect the headphone 10 Amplifier s VOL control to control the headphone or amplifier s VOL to achieve the best result 11 Five buttons on t...

Page 24: ...0 Microphone unit indicator double LED in red the microphone can be used if in green the microphone is limited 11 ON OFF button chairman has the priority 12 The first in switch of chairman unit contro...

Page 25: ...too fast press this key will give a request for slow the speed 9 Microphone on off key 10 Microphone output channel fast key channel 1 5 11 Mute key Prevention on interpreter s cough 12 Channel busy...

Page 26: ...in red and from 7 to 12 in green INPUTS 11 1 Channel audio inputs connect with conference host outputs OUTPUTS 11 1channel audio outputs can send 12 audio outputs to recorder or amplifier and other a...

Page 27: ...interface to connect the SINGAL OUTPUTS of the transmitter host or the OUT of the radiator board OUT connect with next IN POWER INPUT support with AC100V 240V input IR region 4 3 2 Features 1 Powerful...

Page 28: ...2M 20MHz BAND4 Pre emphasis 100 s Deviation 6kHz peak value 7kHz Total harmonic distortion 1 SNR 80dB Frequency response 60 12KHz Input Sensitivity 50mV 1 5V RF output 2 BNC 100mV RMS RF output impeda...

Page 29: ...d speed proportion 9 Built in heating and radiating system four alarms input one alarm output as factory default IP board is optional 10 Park action function can auto call presets or start up tour pat...

Page 30: ...12W weight 2 5Kg Dome Dimension L W H 154X154X152 6 mm 6 Accessories 6 1 SCS E1A Single Earphone 6 1 1 Features 1 Working with interpreter units or SCS 350TA IR receiver units 2 Avoid being interfere...

Page 31: ...i audio quality 6 3 2 Technical Data Model SCS E3A Interface 3 5mm stereo connector Frequency response 80Hz 2KHz Sensitivity 90dB SNR 80dB Distortion 0 1dB Impedance 32 Dynamic range 85 dB Output powe...

Page 32: ...the prompt to install 7 2 1 Login in After installation double click Fully Digital Congress System to login enter the user name and password default user is samcen password is samcen then click OK 7...

Page 33: ...7 3 4 Video Track a Select Camera if there are more than 1pcs cameras choose camera ID which you want to set the ID number is unique Before setting you should make sure video input cable connections a...

Page 34: ...osition click the left button you will hear a Di sound after a few seconds 2 Select Camera Move the mouse to Select Camera select Camera ID in the selection then clicks OK behind of Camera ID box and...

Page 35: ...x select the right baud rate of the camera which you select on Step 2 then click OK behind that selected box you will hear a Di sound after a few seconds You can do the next step only after the Di sou...

Page 36: ...tecol P in the Protecol Type selected box then click OK behind that selected box you will hear a Di sound after a few seconds Finally select 2400 in the Deme Bpe selected box then click OK behind that...

Page 37: ...ove Move the mouse to Save Preset and click after a Di sound appears this preset is applied successfully Microphone 3 Click the down arrow in the selected box of Mic No to 3 click Turn on Preset Mic y...

Page 38: ...you can change the candidate name Pass Ratio when the vote percent of the total pass this the vote is available 7 4 2 Delegate List name of delegates Set similar to Candidate list 7 4 3 Distribute Se...

Page 39: ...ying to in the same time but chairman unit can only agree with one speaker at a time When the first speaker finishes the chairman unit can agree with other applicant When delegate in the application c...

Page 40: ...text and picture to the second screen Fill out text in the box then click on Display Text you can see it on the second screen Click on Display Picture choose the picture which you want to share it wi...

Page 41: ...when the delegate is ON the camera focus to speaker automatically Control the conference by setting the limitation of active microphones and active mode from the control host or software in console P...

Page 42: ...nsole PC Addresser s voice will be transferred to the build in loudspeaker of each contribution unit 1 Need to input some background music and output the audio to amplifier and recorder 8 2 2 System C...

Page 43: ...his international conference needs to interpret up to 31 foreign languages Many auditors will attend this conference and select their own languages to hear SCS should cooperate with central control sy...

Page 44: ...ital Congress System Samcen Industrial Co Ltd Address Units 705 Lingyun Building Dingxin Hi Tech Park Honglang North 2 Rd Bao an District Shenzhen China P C 518101 Tel 86 755 2309 3086 Fax 86 755 2649...

Reviews: