background image

17

Instruction Manual

6-3  클램프·언클램프용 솔레노이드 밸브

6-2  Solenoid valve for Clamp, Unclamp

!

CAUTION

주 의

압력스위치 및 솔레노이드밸브 사용시에는 반드시 전기회로도를 참조해 주
십시오.

Refer to the electric wiring diagram when using a pressure switch and
solenoid valve.

!

CAUTION

[ 그림 / Fig.4 ]

에어클램프 사양의 NC 로터리 테이블의 경우 에어솔레노이드 밸브가 내장
되어 있습니다. 그 배관은 기준사양으로서 다음과 같이 되어 있으므로 전기 
배선시에는 주의해 주십시오.

솔레노이드 ON - 테이블 언클램프
솔레노이드 OFF - 테이블 클램프

The NC Rotary Tables equipped with air clamps are installed with air 
solenoid valves. The standard specifications of the piping are as follows,
which must be taken into consideration into the electric wiring.

Solenoid ON - table unclamp
Solenoid OFF - table clamp

6-2  클램프·언클램프 확인장치

6-2  Clamp, Unclamp Check Device

확실한 작업진행을 위해서 반드시 클램프·언클램프 확인신호를 이용해
주십시오. 압력 스위치의 설정압은 각 클램프 방식에 따라서 다음의 (표 4)
와 같습니다

To prevent mistakes, be sure to check the clamp/unclamp signal. The 
pressure setting of the pressure switch is as follows, according to the 
methods of clampin. (See Table 4)

클램프 확인 / Confirm Clamp

언클램프 확인 / Confirm Unclamp

에어 클램프

Air clamp

0.29 MPa (3.0 kgf/㎠)

(PS1000-R06 [SMC])

0.05 MPa (0.5 kgf/㎠)

(PS1100-R06 [SMC])

[ 표 / Table 4 ]

Unclamp

Clamp

5

Auto Switch

Air Cylinder

Cylinder Stroke

Summary of Contents for SR-200

Page 1: ...Maunted Series Instruction Manual SR 200 SR 250 1 Please read the DANGER and Warning sections before operating the NC Rotary Table Please keep this manual handy as it may answers to any questions you...

Page 2: ...2 NC Rotary Table...

Page 3: ...tion Warning term DANGER WARNING CAUTION IMPORTANT DANGER WARNING CAUTION IMPORTANT Indicates an imminently hazardous situation which if not avoided will result in death or serious injury These warnin...

Page 4: ...14 4 3 1 Air Clamp System 1 4 4 4 Air Purge System 15 4 5 15 5 16 5 1 16 5 2 16 6 16 6 1 NC Rotary Table Clamp 16 6 2 Clamp Unclamp 17 6 3 Clamp Unclamp Solenoid Valve 17 7 18 7 1 18 7 1 1 Worm Gear B...

Page 5: ...ion 1 6 5 2 Periodic Inspection 1 6 6 Description of the NC Rotary Table 16 6 1 Cautions for the Table Clamp 1 6 6 2 Clamp Unclamp Check Device 1 7 6 3 Solenoid Valve for Clamp Unclamp 1 7 7 Descripti...

Page 6: ...machinery and the controllers for installation prior to start installation maintenance or repair of the tilting NC rotary table Loose clothing or limbs may get caught during operation Tighten the bol...

Page 7: ...y workpieces Damage may occur Excessively long or heavy workpieces may result in them being thrown from the rotary table NC Do not exceed the allowable cutting force Product may be damaged and or work...

Page 8: ...Use eyebolts and wireropes when moving the NC rotary table Dropping the rotary table will cause damage and possibly injury CAUTION CAUTION 6 NC Change the lubricant every six months Actual change cycl...

Page 9: ...ompressed air through the air combination lubricator mist separator regulator drain the com pressed air inlet is located on the motor case Drain air filter regularly an auto drain system is recommende...

Page 10: ...earance drawing The maximum table rotation speed is the value at Motor 3000min In order to meet the specifications of the motors attached with absolute encoders the starting point origin of the machin...

Page 11: ...value Model 1 Run out of Table face in rotation 0 020 SR 200 SR 250 2 Parallelism between center of hole and Base 0 020 3 Squareness between Table face and base 0 020 at Table Dia 4 Center hole run ou...

Page 12: ...he gap between the T slot and the guide block is large install the product close to either side of the T slot 4 Use a clamping device to securely fasten the NC rotary table to the machine tool 4 1 1 4...

Page 13: ...he old oil and do not allow any debris of foreign material to enter the tank If contaminated with foreign material the bearings may become stuck and accuracy may diminish Use the following lubricant R...

Page 14: ...oil dust removed page 9 2 Connect the air hose to the air inlet The air inlet PT 1 4 is located on the motor casing See the outside drawing for installation 3 The supply pressure of the air should be...

Page 15: ...thus air pressure is applied to the motor cover As such the air exit must be kept open When the air is discharged out the operator can hear the sound The hydraulic clamping system requires an addition...

Page 16: ...amaged cable 3 Corrosion open circuit in the motor casing CAUTION CAUTION CAUTION The Rotary Table must be rotated while unclamped and processing after positioning must be performed while clamped Inco...

Page 17: ...g are as follows which must be taken into consideration into the electric wiring Solenoid ON table unclamp Solenoid OFF table clamp 6 2 6 2 Clamp Unclamp Check Device 4 To prevent mistakes be sure to...

Page 18: ...eration is less than the optimal value due to thermal expansion Worm gear will not move if backlash is excessively low Measure backlash before adjusting CAUTION CAUTION Appropriate Backlash 1 T SOLT 2...

Page 19: ...using hands Insert a T wrench into the hexagonal recess of the worm shaft Note refer to Worm Gear Backlash Adjustment page 18 of this manual The backlash is reduced when the housing is turned clockwis...

Page 20: ...eripheral devices of the table to confirm that the adjustment is satisfactory HOUSING PLUG O RING O RING OIL CAUTION When installing the housing plug take care not to damage the O ring Fig 6 IMPORTANT...

Page 21: ...o motor please be careful O ring is not lost or damaged there is o ring so that foreign matter does not enter 5 After disassembling Key and ring is decomposed with gear replace the motor 6 Assemble th...

Page 22: ...and cutting fluid from the Table completely and put it on rigid wooden plate to maintain accuracy Apply rust preventive oil to the Table and case or protect them with a wooden cover or wrap them with...

Page 23: ...mulated pitch error of 0 05 with Equation 2 yields Therefore the angle is 206 seconds or three minutes and 26 seconds As illustrated above the lengths and the angles of the peripheral devices are conv...

Page 24: ...8 C1 706 Samchully Machinery 405 820 99 TEL 032 822 4811 FAX 032 822 4377 405 820 99 Namdong daero Namdong gu Incheon TEL 82 32 899 8965 FAX 82 32 721 7607 1544 3122 NC NC Rotary Table Rear Maunted Se...

Reviews: