Assembly and commissioning
Page 24/55
5.1.1
Installation examples
Circuit diagram for installation with
one
module:
1
Housing regulation box
8
Screw connection PG 13.5
2
Interval Timer
9
Junction box
3
Mains switch control
10
Transformer 230 V AC/7.5 kV
4
Fine-wire fuse 4 A
11
Plasma module PL1001A
5
Neutral conductor terminal block
12
Top-hat rail
6
Terminal block
13
Safety timer
7
PE terminal block
For cascading several modules, contact the manufacturer to obtain the appropriate in-
stallation instructions.
Figure 8, Circuit diagram for installation with one module