Doc.-ID: 160319-PT08BA-TG-ExCam IPQ1775 series_en_rev.01.docx, Seite 7 von 40
2
Technical Data
2.1
Parameters of the explosion protection
Identification marks according to
Directive 94/9/EG:
II 2G (zone 1 and 2)
II 2D (zone 21 and 22)
I M2
Explosion protection (gas):
Ex d IIC T6 Gb or
Ex d IIC T5 Gb or
Ex d IIB T6 Gb or
Ex d IIB T5
Explosion protection (dust):
Ex tb IIIC T80°C Db IP68 or
Ex tb IIIC T95°C Db IP68 or
Ex tb IIIB T80°C Db IP68 or
Ex tb IIIB T95°C Db IP68
Explosion protection (mining):
Ex d I Mb
Protection level:
IP 68 (IEC /EN 60529)
Transportation and storage
temperature (EX):
-
60°C…+85°C
Operation temperature (EX):
-
60°C…+80°C (T6)
-
60°C…+85°C (T5)
Ambient temperature (EX)
1
:
-
60°C…+65°C (T6)
-
60°C…+70°C (T5)
Pressure chamber, internal design:
V = 1960 cm3 (bto), free cross sectional area
for free a free gas flow
≥
40% (for Ex group
IIC according to DIN EN 60079-1: 2008)
Nominated body:
TÜV Rheinland (number 0035)
EC Type Examination:
TÜV 14 ATEX 7539 X
IECEx TUR 14.0026X
Test protocol ATEX:
557/Ex.539.00/14
Test report IECEx:
DE/TUR/ExTR14.0026/00
Quality Assessment Report:
DE/BVS/QAR14.0006/00
1
Maximum ambient temperature range relevant for explosion protection might deviate to the maximum functional temperature range.
For maximum functional temperature range (MTBF) see chapter 2.12