Doc.-ID: 131106-PT03BA-SS-ExCam miniZoom_en_rev.01, Seite 5 von 24
Identification marks according to
Directive 94/9/EG:
II 2G (zone 1 and 2)
II 2D (zone 21 and 22)
Explosion protection (gas):
Ex d IIC T6 Gb or
Ex d IIB T6 Gb
Explosion protection (dust):
Ex t IIIC T80° C Db IP67
EC-type examination:
TÜV 09 ATEX 7697 X
Inspection record:
194/Ex.697.00/09
Allowed ambient temperature:
-20°
C … +50° C
2.2
Electrical parameters
Camera:
Supply voltage:
+12 V DC to +30 V DC
Reference power:
+24 V DC
Power input:
67 mA to 208 mA
Maximum power input:
2.5 W (without heating)
Heating (optional):
Supply voltage:
+12 V DC to +24 V DC
Reference power:
+24 V DC
Power input:
ca. 1000 mA
Maximum power input (-20°C):
10 Watt
2.3
System cable SKAxx
Outer diameter:
9.4 mm
Max. bending radius:
150 mm
Material outer sheath:
PUR
– flame retardant according to
IEC 60322-1-2
Color outer sheath:
RAL 9005 matt
Video:
1x75
Ω Koax, 19x0.127mm tinned AWG 24,
plated copper braid, shielded
RS 422:
2 x 2 x 0.25 mm
2
(twisted pair) Cu shielded
double wrapping foil
Supply voltage camera:
2 x 0.75 mm
2
, polyolefine insulated
Supply voltage heating:
2 x 0.75 mm
2
, polyolefine insulated