background image

 
 
 

 
 

Doc.-ID: 190402-PT08BA-ES-ExCam XF-Q1785_EN_rev.00.docx, Page 16 of 32 

5.3.2 

Routing via ExConnection Rail (optional accessories) 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Fig. 5-7 ExTB-3 -> ExConnection Rail 

 
In case of routing the ExTB-3 into an ExConnection Rail, larger installation distances can 
be covered.  
 

Note: 
In hazardous areas, the ExConnection Rail (optional accessories) acts as a PoE+ switch, 
a  media  converter  from  copper  to  fibre-optic  cable,  as  well  as  a  power  supply  for  the 
cameras. 

 

Attention! 
Cables and wires must comply with the requirements of the  
IEC 60079-0/1/7 & 14. 

 

Attention! 
The  supply  line  must  have  a  sufficient  cross-section.  The  cable  pro-
tection must comply with national and international regulations. 

 
 
5.3.3 

Appropriate cables & cable entries 

 
An integral part of the device safety is the correct selection of the cables, wires and cable 
entries. 
 

Attention! 
Cables  and  wires  must  comply  with  the  requirements  of  the  
IEC 60079-0/1/7 & 14. 

 

 

 

Summary of Contents for ExCam XF Q1785

Page 1: ...ExCam XF Q1785 User Manual ...

Page 2: ...Rail optional accessories 16 5 3 3 Appropriate cables cable entries 16 5 3 4 Cable kits plug and play connection packages 18 5 3 5 Fusing 19 5 3 6 Plug assignment RJ45 20 5 3 7 Tests prior to switching on voltage 21 6 Working inside the camera housing Ex d 21 6 1 Work preparation 21 6 2 Opening the pressure resistant housing 22 6 3 Removing inserting an SD memory card 24 6 4 Hardware Reset 25 6 5 ...

Page 3: ... kits 19 Tab 5 4 Recommendation for fusing 19 Fig 5 10 Plug assignment RJ45 20 Fig 6 1 Removing the weather protection roof 1 2 this illustration is an example 22 Fig 6 2 Removing the weather protection roof 2 2 similar illustration 23 Fig 6 3 Opening the ExCam XF Q1785 similar illustration 23 Fig 6 4 Reset Button 25 Fig 7 1 Axis IP Utility 28 Fig 7 2 User Interface to operate the wiper 28 Fig 7 3...

Page 4: ... see other approv als please visit our website at www samcon eu When designing the ExCam XF Q1785 we attached a very high importance to safety mechanical precision and high quality of stainless steel 2 Technical data 2 1 Explosion protection Identification marks Model key T08 VA2 3 K3 BOR5 LL H 005 A T acc to Directive 2014 34 EU II 2G zone 1 and 2 II 2D zone 21 and 22 Explosion protection gas Ex ...

Page 5: ...ical power consumption 7 7 W 2 3 Connection cable Ex d Ex e ASKDP03 T Description Data transfer and power supply of the camera module compliant with DIN EN 60079 14 Jacket colour green GN similar to RAL3001 Outside diameter 17 00 0 5 mm Bending radius 10 x Da when installed and 5 x Da after relocation Data line 4 x 2 x AWG22 1 CAT 6a Performance elements 3G1 5 BK BU GN YE Properties PUR halogen fr...

Page 6: ... com products axis q1785 le 2 5 Other technical data Tab 2 1 Other technical data Camera Ex d Terminal box Ex e Permissible ambient temperature 0 C 60 C for PoE power supply 60 C 60 C in the event of additional 24 V DC power supply 60 C 55 C Protection class as per EN 60529 IEC 529 IP68 Test conditions 24h 3m water column 5 C IP66 Housing material stainless steel mat no 1 4404 polyester resin Weig...

Page 7: ...t permitted The camera is to be operated in sound conditions and in the in tended way Attention Only original parts of SAMCON Prozessleittechnik GmbH may be used for repairs Repairs concerning the explosion protection may only be carried out in accordance with the nationally applied regulations and by SAMCON Prozessleittechnik GmbH Attention Prior to installation take external sources of heat or c...

Page 8: ...a work approval has to be obtained When opening the pressure resistant enclosure under voltage it is absolutely necessary to prevent potentially explosive atmosphere To ensure the best image quality delivered by the network camera plan the installation site carefully consider light conditions object distance or size angle and minimum object distance to the focus Use appropriate tools and aids When...

Page 9: ...of doubt take appropriate security measures Drawings for drilling hole patterns and further information can be viewed on our product page Quick link https www samcon eu en products network excam xf q1785 Option mounting accessories Wall bracket WMB WALL MOUNT EXCAM XF 01569 001 Wall bracket for devices of T08 VA3 series Suitable for hanging the camera on walls Material stainless steel 1 4404 Load ...

Page 10: ...s equipped with an electrical connection cable of the type ASKDP03 T The maximum transmission range from the camera to the next active network interface is 100 meters and can be individually specified by the client The user is NOT authorised to do electrical connection procedures inside the pressure resistant enclosure 5 1 Potential equalization Fig 5 1 ExCam XF Q1785 potential equalization The po...

Page 11: ... Uin 26 V DC Power consumption approx 40W 60 C depends on the temp Power supply for the camera PoE Power supply PoE IEEE 802 3af 802 3at type 1 class 3 Reference voltage 48 V DC 44 54 V DC Maximum power consumption 12 95 W Typical power consumption 7 7 W Attention The electric connection of the device is exclusively carried out via the ExTB 3 terminal box Attention Never open the Ex e terminal box...

Page 12: ...age 12 of 32 Fig 5 2 Camera Ex d and terminal box Ex e Video Tutorial Please view our video tutorial SAMCON 01 Wiring the cable SKDP03 T to the junction box ExTB 3 https go samcon eu v01 Fig 5 3 Video Tutorial ExTB 3 Screw on the terminal box ExTB 3 ExTB 3 ...

Page 13: ...PE 2 5 mm2 Flex Tx WH OG 1 0 32 mm2 Solid conductor Tx OG 2 0 32 mm2 Solid conductor Rx WH GN 3 0 32 mm2 Solid conductor Rx GN 4 0 32 mm2 Solid conductor PoE 48 VDC WH BU 5 0 32 mm2 Solid conductor PoE 48 VDC BU 6 0 32 mm2 Solid conductor PoE GND WH BN 7 0 32 mm2 Solid conductor PoE GND BN 8 0 32 mm2 Solid conductor GND SHD YE GN PE 2 5 mm2 Flex L BK 9 1 5 mm2 L 24VDC L BU 10 1 5 mm2 L 24VDC PE YE...

Page 14: ... terminals in order to prevent alien crosstalk Make sure that the foiling cannot cause any short circuit of the data pairs Attention Bring the twisted pair composite approximately 10mm close to the terminals in order to ensure the interference immunity Attention Use only terminals approved by SAMCON Attention Finally check your network installation by per Class D Link Test ...

Page 15: ...ing from the ExTB 3 into the safe area the power supply and the voltage signal is led from the safe area to the terminal box Please observe the terminal box assignment as described above Attention Cables and wires must comply with the requirements of the IEC 60079 0 1 7 14 Attention The supply line must have a sufficient cross section The cable pro tection must comply with national and internation...

Page 16: ... a media converter from copper to fibre optic cable as well as a power supply for the cameras Attention Cables and wires must comply with the requirements of the IEC 60079 0 1 7 14 Attention The supply line must have a sufficient cross section The cable pro tection must comply with national and international regulations 5 3 3 Appropriate cables cable entries An integral part of the device safety i...

Page 17: ...g guidelines please visit our website Particularly for installations requiring a suitable barrier gland make sure that you handle them correctly and observe the rules and notes given in the respective mounting and as sembly instructions We show the basic procedures in the following video tutorial Video Tutorial Observe our video tutorial SAMCON 02 Mounting and installing Ex d barrier glands to ExC...

Page 18: ...e set includes 10 meters SKDP03 T system cable digital 1 x barrier gland Ex d 5 ml Loctite 243 screw locking 1 x CAT6 RJ45 industrial plug 1 x documentation ASKDP03 T CABLE EXCAM 10M 01543 001 This cable set includes 10 meters ASKDP03 T system cable digital 1 x bolted connection Ex d 1 x bolted connection Ex e 5 ml Loctite 243 screw locking 1 x CAT6 RJ45 industrial plug 1 x documentation a b c d 1...

Page 19: ...01 This cable set includes 95 meters ASKDP03 T system cable digital 1 x bolted connection Ex d 1 x bolted connection Ex e 5 ml Loctite 243 screw locking 1 x CAT6 RJ45 industrial plug 1 x documentation Tab 5 3 Available cable kits 5 3 5 Fusing PoE power supply requires no fuses The power supply fusing depends on the cable cross section and length Attention The protection recommendation for fusing r...

Page 20: ...hence there is no power ON priority which has to be observed Attention Use appropriate RJ45 plugs Check the cable shielding cross section and the outside diameter Attention It is imperative to ensure a correct routing of the individual wires according to the EIA TIA 568B Attention Finally check your network installation by per Class D Link Test Detailed instructions on how to connect an RJ45 plug ...

Page 21: ...ss of warranty Attention Do not switch on the camera at temperatures below 0 C 6 Working inside the camera housing Ex d The customer may open the housing only if it is absolutely necessary Only exchanging the SD memory card or a hardware reset are reasons for this 6 1 Work preparation Attention Prepare your work carefully and in accordance with the relevant regulations Attention Depending on class...

Page 22: ...housing requires disassembly and working in a safe i e non explosive area Attention Heed that you do not damage the thread surface of the flame proof gap Attention Heed that you do not damage the housing seals Keep them clean Attention Make sure that the wiper in placed in the central position ExCam XF Q1785 is equipped with a weather protection roof Prior to starting you work the roof shall be re...

Page 23: ...there is LOCTITE 243 chemical basis is dimethacrylate ester applied to prevent the bolted connection from unintentional loosening because of impacts and vibrations and to seal them tightly It is not permitted for the customer to open the front side sight glass flange There is no need of such an action Fig 6 3 Opening the ExCam XF Q1785 similar illustration Carefully pull out the cable and supply f...

Page 24: ...at seal blue RAL5012 The flat gasket is loosely attached to the cable and power supply flange It is fixed only by the bolted connections Attention Make sure not to damage the surface of the drill hole and the shaft fit ting of the flame proof gap Attention Pay attention not to damage the seals Keep them clean 6 3 Removing inserting an SD memory card Note The ExCam XF Q1785 has a slot for a micro S...

Page 25: ... there is a DHCP server available in the network the IP address will be the following 192 168 0 90 subnet masking 255 255 255 0 5 IP address and password can be redefined If the hardware reset is not satisfacto ry or the network camera shows serious conflicts or does not work as usual errors in the browser visualisation frozen images control commands no longer pro cessed slowing down of the system...

Page 26: ...oth and de grease it with a suitable cleaning agent Then re grease it with lubricant suitable for this specific application e g Mo lykote P 40 gel for standard applications or special grease OKS 403 in the event of heavy seawater influence The screwed connections of flange and body components must always be tightened crosswise at a torque of 3 Nm Do not tighten the screw too strongly It can cause ...

Page 27: ...rly in surroundings with fluorescent tubes In such a case the applicable settings have to be carried out within the menu System Options Ad vanced Plain Config User root Password root 7 1 Browser Support A list of the currently supported web browsers operating systems required add ons etc can be viewed at http www axis com techsup cam_servers tech_notes browsers htm 7 2 Assigning the IP address The...

Page 28: ...etwork segment physical subnet as the computer on which the AXIS IP Utility is run ning The network signature of ExCam XF Q1785 is AXIS Q1785 see Figure 7 1 MAC address and serial number for clear device identification are also detected and displayed Fig 7 1 Axis IP Utility 7 3 Password Identification The following user name is set at the factory root The following password is set at the factory r...

Page 29: ...s must be adhered to The required maintenance intervals are specific to the individual devices The operating company has to determine these intervals depending on the application parameters The maintenance tasks especially include examination of parts on which the ignition protec tion depends e g proper condition of the casing seals and cable entry points If maintenance measures are necessary they...

Page 30: ...emove the wiper Simply pull out the old wiper lip upwards and insert the new one Fig 8 1 How to replace the wiper lip 9 Disposal Recycling When disposing of the device nationally applicable regulations must be observed This Document is subject to alterations and additions 10 Drawings 3D models All drawings 3D models certificates and other information are available in the download area of the produ...

Page 31: ...ou wish additional technical information please contact us at support samcon eu 11 Certificates and further documentation Certificates and further documentation are available in the download area at the product website https www samcon eu en products network excam xf q1785 ...

Page 32: ...Schillerstrasse 17 35102 Lohra Altenvers Germany www samcon eu info samcon eu Phone 49 6426 9231 0 fax 31 ...

Reviews: