Doc.-ID: 220518-PT20BAU-SS-Ex Installation Manual rev.01.docx, Page 5 of 24
WARNUNG:
NICHT INNERHALB EINES EXPLOSIONSGEFÄHRDETEN BEREICHS ÖFFNEN
Sicherheitshinweise in der Installationsanleitung beachten!
--------------------------------------------------------------------------------------------------------------------
WARNING:
DO NOT OPEN IN POTENTIALLY EXPLOSIVE ATMOSPHERES
Observe the safety instructions in the installation guide!
--------------------------------------------------------------------------------------------------------------------
ВНИМАНИЕ:
НЕ ОТКРЫВАТЬ в потенциально взрывоопасных средах
Соблюдайте инструкции по технике безопасности в руководстве по установке!
AVERTISSEMENT:
NE PAS OUVRIR EN ATMOSPHÈRES EXPLOSIBLES
Respectez les consignes de sécurité dans le guide d'installation!
Note:
If the EPLs or temperature classes of the used secondary ignition protection classes (ix,
op is, etc.) are lower than the ones for the primary protection class, the identification of the
secondary protection class shall be used, or the effect shall be shown in square brackets.
For example: II 2G Ex db op is [op is Ga T4] IIC T6 Gb.
Note:
IECEx marking is always an integral part of the identification plate.
EAC-Ex marking and other affiliated certificates are marked depending on the approval
status.
2.1.2
Standard basis and certificate
Basic EX standards:
IEC
EN
DIN EN
IEC 60079-0:2017
EN 60079-0: 2018
DIN EN 60079-0: 2019
IEC 60079-1:2014
EN 60079-1: 2014
DIN EN 60079-1: 2015
IEC 60079-28:2015
EN 60079-28: 2015
DIN EN 60079-28:2016
IEC 60079-31:2013
EN 60079-31: 2014
DIN EN 60079-31: 2014
Named testing laboratory:
TÜV Rheinland (number 0035)
EU type approval certificates:
TÜV 21 ATEX 8696 X
(2021)
IECEx TUR 22.0076
(2022)
Supplement / Rev. Index:
00