Safety instructions
582115110-EN-indC-Pump-01D140-01D140E.docx
26/05/2020
15
Tubing
Recommendations for pipes.
Keep hoses away from traffic areas, moving parts and hot
areas.
Never subject product hoses to temperatures above 60 °C /
140°F or below 0 °C / 32°F.
Do not use hoses to pull or move equipment.
Tighten all connections, hoses and connectors before
commissioning the equipment.
Check hoses regularly, replace them if damaged.
Never exceed the maximum working pressure stated on the
hose (MWP).
For fitting the hoses and gun: PPE is mandatory.
Tighten to block stop (hoses + gun).
Normal stop
To make a normal stop:
Use the air regulator to gradually decompress the pump.
Summary of Contents for 01D140
Page 23: ...Identification 582115110 EN indC Pump 01D140 01D140E docx 26 05 2020 23 Pump model 01D140E...
Page 29: ...General specifications 582115110 EN indC Pump 01D140 01D140E docx 26 05 2020 29 Dimensions...
Page 55: ...Spare parts 582115110 EN indC Pump 01D140 01D140E docx 55 12 Spare parts 12 1 Exploded view...