SAMES KREMLIN
- 3 -
N° : 578.055.110-UK-1906
CARTRIDGE AND NEEDLE
Unscrew the needle (24) - (be careful with springs 18 and 19).
Take driving-piston (15) and disengage it so that the rear part of the needle appears it from the rear
side of the gun body.
Hold the rear side of the needle with a pliers and thanks to a spanner unscrew and remove nut (17).
Remove driving-piston (15).
Unscrew air cap (1), spray tip (5) as well as the seat-holder (30) from the gun.
Loosen fluid leakage detector (20) by two turns.
Firmly, push needle to extract it as well as cartridge-needle assembly (26) from the front side of the
gun body.
Insert the cartridge and needle assembly into the front side of the gun.
IMPORTANT : thanks to a brass tube with a suitable diameter, firmly push cartridge to
put it back properly inside the gun.
Screw fluid leakage detector (20).
Place the piston (11) and the driving-piston (15) on the back part of the needle.
Screw and firmly install the nut (17). Reassemble the parts at the back part of the gun.
Screw the seat-holder (30), tighten it and respect recommended screwing torque.
Reinstall the nozzle (5) and the air cap (1).
Before reassemblying the different components :
- Clean the parts with the appropriate cleaning solvent using a brush,
- Install the seals if necessary after having lubricated them with PTFE grease,
- Install new parts if necessary.