SAMES KREMLIN
- 4 -
N° : 578.095.120-UK-1905
INSTALLATION DIAGRAM
Captions :
A
Explosive area area 1 (Z1) or area 2 (Z2) :
spray booth
1
Pump
2
Filter
3
Airless automatic gun
4
Conductive
HP fluid hose
5
Air hose (control air)
6
3 way-valve or electrovalve
1 - By means of a conductive high pressurefluid hose (3), connect the gun fluid fitting to the pump.
Tighten firmly the fittings.
2 - By means of an air hose (4), connect the gun 'Control air' fitting to the valve or the electrovalve (5)
that will control the opening and the closing of the gun.
A minimum pressure of 3 or 4 bar / 43.5 or 8 psi is necessary to control the gun
(
control air).
Nota : The gun
must be
grounded by,
at least,
one of the three next solutions :
by means of the fixing device on the machine,
by means of the static conductive air hose,
by means of the conductive or static conductive fluid hose.
The ground resistance between the gun and the floor must be ≤ 1 MΩ.