CONNECTION OF THE CONTROL UNIT AND OF THE FLUID PART
The CYCLOMIX
TM
MICRO must be
connected to a dry and clean
compressed air (minimum 4 bar / 58 psi)
and to a single phase electric supply
(115 V / 230V) connected to an isolating
switch. The network ground will be
connected in the control bay on a contact
provided.
Before connecting the
CYCLOMIX
TM
MICRO, be certain the
mains voltage is the same than the
one of the CYCLOMIX
TM
MICRO (230
V).
If no, open the electric box removing the
protective housing (10) and shift the
staple (230V
115V).
The air connection of the CYCLOMIX
TM
MICRO is Female 1/4 G (air inlet = R1
and air outlet = R2).
The connection between the control unit
and the fluid module is carried out via the
provided cable, length 5 m / 196.85 ft.
For lengths up to 5 m / 196.85 ft connect
the cables between them (male-female).
The connection between the two
cables must not be in the explosive area.
A valve fitted with fittings is supplied with
the CYCLOMIX
TM
MICRO. It will be
mounted on the gun air inlet : it enables
to shut off quickly the fan air (priming,
flushing stage).
Fuse 160 mA
for CYCLOMIX
TM
MICRO
with serial number < to 09Y1080
Fuse 315 Ma
for CYCLOMIX
TM
MICRO
with serial number >to 09Y1080
Connection of the fluid inlets :
The fluid inlets are M 1/2 JIC.
We advice you to install AIRMIX
filters on the fluid inlets (catalyst and
base).
The base(s) and the base solvent are
connected on the color changer installed
on the CYCLOMIX
TM
MICRO.
The catalyst is connected :
- directly on the elbow installed before
the non-return valve,
- or on the color changer (cata and cata
solvent) installed in the CYCLOMIX
TM
MICRO.
It depends upon the configuration of the
CYCLOMIX
TM
MICRO.
The air connection is made on the two
G 1/4 connecting parts.
Air inlet /
outlet
Base(s) and solvent base
Catalyst
SAMES KREMLIN
Page 14
Manual : 573.191.112