PARAMETERS FOR CYCLOMIX
TM
MICRO WITHOUT CATALYST FLUSHING
Parameters
Description
Factory
adjustment
For the 3
programs
Your
adjustment
Program 1
Your
adjustment
Program 2
Your
adjustment
Program 3
Parameter of the password
Mixing ratio parameter. Percentage
of catalyst in the base, from 0% to
160%
50 %
Parameters of the mixed fluid life
time
Minimum value : 1min
Maximum value : 480 min
100 min
Regeneration volume parameter in
cubic centimetre
Minimum value : 100 c.c
Maximum value : 10 000 c.c
5000 c.c
Flushing volume during which the
CYCLOMIX
TM
MICRO
flushes
with solvent
Minimum value : 10 c.c
Maximum value : 10 000 c.c
500 c.c
Mixing tolerance parameter to
enable the
CYCLOMIX
TM
MICRO
to make an alarm.
Minimum value : 1%
Maximum value : 100%
5 %
Parameter of the fluid dry extract to
count the VOC
Minimum value : 0%
Maximum value : 100%
55 %
Parameter of volume by tooth of
base flowmeter. You must change
that parameter when changing the
flowmeter.
Minimum value : 0.01 c.c
Maximum value : 2.00 c.c
0.24 c.c
(Value of
origin)
Parameter of volume by tooth of
catalyst flowmeter. You must
change that parameter when
changing the flowmeter.
Minimum value : 0.01 c.c
Maximum value : 2.00 c.c
0.24 c.c
(Value of
origin)
Parameter of time between the air
opening and the fluid opening
before fault
Minmum value : 1 s
Maximum value : 6 s
6 s
(Value of
origin)
Parameter of the proportioning test
: to activate this parameter
-
SAMES KREMLIN
Page 20
Manual : 573.191.112