TROUBLESHOOTING
For any intervention on the CYCLOMIX
TM
MICRO :
- Flush the circuits,
- Shut off the compressed air,
- Depressurize the hoses by triggering the gun,
- Shut off the electric supply.
If a problem occurs during the operating of the CYCLOMIX
TM
MICRO, some alarm will be displayed on
the screen of the CYCLOMIX
TM
MICRO.
Enter
to acquit each alarm (we advice you to keep active the error 6 even if you can can desactivate
it).
TROUBLES
CAUSES
SOLUTIONS
BASE flowmeter blocked.
Check the fluid circuit (pump, valve).
Clean or change.
Check or install a filter upstream the
flowmeter.
CATA flowmeter blocked.
Check the fluid circuit (pump, valve).
Clean or change.
Check or install a filter upstream the
flowmeter.
Incorrect mixing ratio
Flow improperly adjusted
Check the pressure differential : the
CATA pressure must be higher than the
BASE pressure of 15%
Time between air opening and fluid
opening upper than 6 s
Flow switch blocked
Air leak
Trigger the gun quickler.
Change the flow switch.
VP6 valve leaking
Remove VP6 and check the correct
operating.
Change the valve if necessary.
(Caution: this error
appears only in F1 mode
(production) and except
the priming
/regeneration stage)
There is no signal from the flow-
switch whereas there are impulses on
the base flowmeter or on the catalyst
flowmeter.
Check the good operation of the flow-
switch. Change it if necessary.
Control the good operation of the
electronic card.
Increase the value of P12.
SAMES KREMLIN
Page 33
Manual : 573.191.112