SAMES KREMLIN
- 2 -
N° : 578.027.110-UK-1708
OPERATION TO CARRY OUT
FREQUENCY
D
W
M
Q
H
Y
GENERAL
Check earthings.
X
Check leakage from the fittings.
X
Check hoses.
X
Operate the valves.
X
GUN
Clean the outside of the spray nozzle with a soft brush
and solvent.
X
Flush the spray gun.
X
When the spraying system will not be used for an
extended period of time, take off the nozzle and
immerse it in a solvent-filled container.
X
Remove the air valve, clean it if necessary. Grease it
as well as the spring before assembling.
X
Change the air valve. Grease it as well as the spring
before assembling.
X
Remove the needle as well as the rear line and the
complete air valve. Clean the parts and grease them
before assembling.
X
Remove the gun, clean the parts, change the seals
and
the
defective
parts.
Grease
them
before
assembling (refer to seal kit and servicing kit).
X
D : daily
W : weekly
M : monthly
Q : quarterly
H : half-yearly
Y : yearly
Nota : Frequencies are given as a clue. They must be adapted by the maintenance service
of the user for every installation according to the product, the working cadence and the
working pressure.