background image

SAMES KREMLIN

- 2 -

N° : 578.027.110-UK-1708

OPERATION TO CARRY OUT

FREQUENCY

D

W

M

Q

H

Y

GENERAL

Check earthings.

X

Check leakage from the fittings.

X

Check hoses.

X

Operate the valves.

X

GUN

Clean the outside of the spray nozzle with a soft brush
and solvent.

X

Flush the spray gun.

X

When the spraying system will not be used for an
extended period of time, take off the nozzle and
immerse it in a solvent-filled container.

X

Remove the air valve, clean it if necessary. Grease it
as well as the spring before assembling.

X

Change the air valve. Grease it as well as the spring
before assembling.

X

Remove the needle as well as the rear line and the
complete air valve. Clean the parts and grease them
before assembling.

X

Remove the gun, clean the parts, change the seals
and

the

defective

parts.

Grease

them

before

assembling (refer to seal kit and servicing kit).

X

D : daily

W : weekly

M : monthly

Q : quarterly

H : half-yearly

Y : yearly

Nota : Frequencies are given as a clue. They must be adapted by the maintenance service
of the user for every installation according to the product, the working cadence and the
working pressure.