Index revision : C - July 2021
20
7132
6.2.
Installation
The Inogun M gun is installed either on the different types of cart (vibrating table, tank or
penetrant testing) or on a manual station of a booth (see corresponding operating manuals).
6.2.1.
Installation of an extended nozzle (option)
The Inogun M gun can be equipped with optional extended nozzles for flat spray and round
spray (
• Switch off high voltage,
•
Step 1:
Manually unscrew the nozzle nut (1),
•
Step 2:
Remove the electrode support
assembly (3) and its flat jet or round jet
deflector (2).
WARNING : When installing an extended nozzle
from length 450 mm, it is imperative
to check the presence of the reinfor-
cing sleeve (4) (P/N 900020899) in
the reinforcing electrode support
(
•
Step 3:
Install the extended nozzle assembly
(5) into the gun barrel.
•
Step 4:
Manually screw the new extended
nozzle nut (6).
• Switch on high voltage.
1
4
2
3
5
6