Index revision : C - July 2021
21
7132
6.2.2. Procedure for mounting the counter-electrode
The Inogun M can be equipped with an optional counter-electrode (
• Switch off high voltage,
•
Step 1:
Unscrew the 2 screws (1 and 2)at
the back of the gun.
•
Step 2:
Slide the hook towards the front of
the gun.
•
Step 3:
Insert the conductive hook (3), slide
it to the stop and then tighten the 2 KA 30 x
20 screws (4) to a torque of 0.65 N.m.
•
Step 4:
Place the counter-electrode (1) on
the nozzle nut of the gun and slide it until
the banana plug (2) is in contact with the
conductive hook (3).
• Switch on high voltage.
1
2
3
4
1
2