background image

 

Index revision : A

10

7129

3.  Characteristics

(*) - The measurement of the viscosity of a water-soluble paint using a consistometric cup leads

to very significant errors. In effect, these paints are thixotropic: their viscosity decreases with the

intensity of agitation and with the time for which they are stirred. At rest, these paints are highly

viscous substances; in contrast, in movement, they become not very viscous substances. The

viscosities shown are indicative for paint stirred just before being measured with a cup.

(**) - Any other use is prohibited

Footprint (W x H x P) 

1100 x 1640 x 650

Mass

140 Kg

Maximum operating altitude

2,000 m

Min/max ambient temperature

5°C - 40°C

Maximum relative humidity 

of 80% for 

temperatures of up to 31°C, then linear 

decrease until 50% relative humidity at 

40°C

Maximum of 80% without condensation

Operating voltage

100 kV maximum 

Maximum current

500 µA max.

Electrical power supply:

- Voltage 

- Frequency

- Max. power consumption (50 VA 

power supply  generator)

Europe version

230 V 

± 

10%

50 -60 Hz

200 VA

CSA Version

110V

 

± 

10%

50 -60 Hz

200 VA

Voltage surge

Category II overvoltage according to standard IEC 

61010-1:2010

Compressed air pressure 

7 bars (101 psi) 

±

 

0.5 bars

Max. air flow

Depends directly on the type of pump and the product 

flow 

Product viscosity

Depends on the product used

Max. product flow 

According to the viscosity and the thixotropy of the 

product (*) and according to the pump

Products 

Non-flammable paints with a resistivity that must be 

between 1k

Ω

.cm and 250 k

Ω

.cm. (**).

WARNING :   Not appropriate and also dangerous for 

the solvent-based paints, resistive liquids and flamma-

ble liquids that form explosive atmospheres.

Summary of Contents for ISOCUBE

Page 1: ...Index revision A 1 7129 User manual SAMES KREMLIN SAS 13 Chemin de Malacher 38240 MEYLAN FRANCE Tel 33 0 4 76 41 60 60 www sames kremlin com ISOCUBE Isolating cabinet...

Page 2: ...enance of our equipment all year long A catalogue is available on request Select the training programme type of learning method and skills you need from our range to meet your production targets These...

Page 3: ...the cabinet to the installation s general safety loop 14 4 3 3 Connection of a pump 15 4 3 4 Connection of the sprayer s 15 4 3 5 Connection of the product regulator 16 4 3 6 Connection of the high vo...

Page 4: ...ped with systems to prevent this type of risk Potential source of elec tric shock Measures Means applied Voluntary or involuntary contact with the pump or the paint drum Automatic earthing of all part...

Page 5: ...ensure and check that all operators have read and understood the user manuals for peripheral electrical devices present within the spraying perimeter 1 4 Warnings WARNING This equipment may be hazardo...

Page 6: ...ncrete flooring or a metal grating in the spray ing area Never cover the floor with an insulating covering In potentially explosive loca tions the floor assemblies must be antistatic in accordance wit...

Page 7: ...ctrostatic projection equipment according to the instructions contained in this user s manual Only use metal containers to hold the cleaning liquids and connect to ground according to a safe procedure...

Page 8: ...cabinet Rep 1 consists of An electro pneumatic box Rep 2 A 100kV short circuiter Rep 3 located on the top of the cabinet A stirrer option And enables the integration of A generator An external emerge...

Page 9: ...face Rep Designation 1 Main switch lockable 2 On off button green 3 Air supply pressure 4 Pressure flow regulator 5 Pressure pump power supply 6 Stirring supply pressure 7 Emergency stop 8 Voltage pr...

Page 10: ...to 31 C then linear decrease until 50 relative humidity at 40 C Maximum of 80 without condensation Operating voltage 100 kV maximum Maximum current 500 A max Electrical power supply Voltage Frequency...

Page 11: ...O 8573 1 The values are given for a temperature of 20 C 68 F at atmospheric pressure Characteristics Value Maximum dew point at 6 bar 87 psi Category 4 i e 3 C 37 F Maximum particle size distribution...

Page 12: ...in a case that can be handled using a forklift truck or pallet truck Once out of its packaging the cabinet is handled using the forklift truck or the pallet truck but also using straps through the fo...

Page 13: ...connection the whole time Ensure that the suspension hooks are frequently stripped The elements of the ISOCUBE cabinet electro pneumatic box security systems are delivered connected Connections of the...

Page 14: ...Step 2 Run the generator cable through a second cable gland then connect it to termi nals X1 5 and X1 6 4 3 2 Connection of the cabinet to the installation s general safety loop Step 1 Run the genera...

Page 15: ...he bottom of the cabinet Step 2 Connect the compressed air hose to the quick coupler D 10 4 3 4 Connection of the sprayer s Connect the two painting hoses via the two cable glands provided for this pu...

Page 16: ...left Step 2 Connect the generator s high voltage cable to the body of the pump at the link for all the equipotential links Step 3 Connect the high voltage cable present in the Isocube cabinet from the...

Page 17: ...edge of the recep tacle Step 2 Connect the black equipotential wire to the body of the pump at the link for all the equipotential links Step 3 Connect the compressed air hose to the quick coupler D 8...

Page 18: ...OCUBE is then ready to operate If the door is left open or not locked this second press has no effect 4 5 1 Placement of the paint drum Place the paint drum on the receptacle in the isolating cabinet...

Page 19: ...rinsing operations To restart lock the door and then press single click on the green button 4 7 Emergency stop The emergency stop switches off all the energies However residual pressure may remain in...

Page 20: ...with a multimeter in the ohmmeter position between the earth terminal of the ISOCUBE and the earth terminal of the electrical socket on the power cord The value must not exceed 2 5 1 1 Insulating cab...

Page 21: ...windows of the air pressure indicators may be cleaned with a cloth soaked in water or non aggressive non greasy and non flammable solvent Do not use butyl glycol In this case make sure that the solve...

Page 22: ...ing in the compartment of the tank and the pump Remove the causes of the leak clean and dry the dirty parts Short circuiter defective Check its operation then repair and replace it if neces sary Noise...

Page 23: ...aintenance Level 2 Corrective maintenance Level 3 Exceptional maintenance Rep Reference Designation Qua ntity Unit of sale Spare parts level 910027658 ISOCUBE 1 1 1 ISOCUBE cabinet equipped see 8 3 pa...

Page 24: ...nce Level 2 Corrective maintenance Level 3 Exceptional maintenance Rep Reference Designation Qua ntity Unit of sale Spare parts level 910028401 ISOCUBE 1 1 1 ISOCUBE cabinet equipped see 8 3 page 25 1...

Page 25: ...Index revision A 25 7129 8 3 ISOCUBE cabinet equipped DES07179 1 2 3 4 5 7 8 11 10 9 6...

Page 26: ...X9SVCB121 C M 4x16 nylon screw containing fibreglass 4 1 1 5 110001738 Alligator clip 20A 1 1 3 6 110002187AT Cable gland 1 1 3 7 910019962 Short circuiter 100 kV see RT Nr 6442 1 1 3 8 110000110AT C...

Page 27: ...u anti ty Unit of sale Level Spare parts 149220760 Fitted stirrer 1 2 1 539280102 Blue polyurethane hose D 6x8 1 m 3 2 049220700 Stirrer see leaflet Ref 573 303 050 1 1 3 3 552486 Female female sleeve...

Reviews: