4.2. Installation
• The ISOCUBE isolating cabinet must be installed and used outside of any explosive area.
• The emergency stop must be free to access in order to facilitate any manoeuvres.
• Ensure the correct earth connection of the parts to be painted (open electrical connec-
tion of the electrical earthfeeder, cleanliness of the metal suspension hooks).
• Be sure to maintain this good connection the whole time. Ensure that the suspension hooks
are frequently stripped.
• The elements of the ISOCUBE cabinet (electro-pneumatic box, security systems) are
delivered connected.
• Connections of the cabinet:
• Connect the earth of the cabinet using the earth wire fitted with a terminal.
• Connect the compressed air inlet hose (customer supplied) (3/8" BSP female, Ø 8 inte-
rior, length 10 m maximum) to the supply valve.
• Connect the AC power cord to the electrically adapted network (the supply voltage
is indicated on the nameplate located on the cabinet).
Note: the
symbol means
"Caution Possibility of electric shock".