Index revision : A
4
7129
1. Health and safety instructions
This document contains links to the following operation manuals:
•
for the
100 kV short-circuiter.
•
for the installation guide for flammable conductor paint antenna.
•
See leaflet ref: 573 303 050
for the stirrer (option).
1.1. Marking
1.2. Simplified analysis of the potential sources of electric shocks
When non-flammable products (defined in standard NF EN 50348 appendix A) are used, the
inflammation risk is by definition zero. However, these products contain large quantities of water
which quickly store enough quantities of energy to cause electric shocks.
That is why the ISOCUBE insulating cabinet is equipped with systems to prevent this type of risk.
Potential source of elec-
tric shock
Measures
Means applied
Voluntary or involuntary
contact with the pump or
the paint drum
Automatic earthing of all parts
under HV if the door is opened
Time to implementation of
security measures of less
than 2 sec
Voluntary or involuntary
contact with the sprayer
injector
Limitation of the length of the
product hose to 18 m max and
the capacity of the product
drum to maximum 60 l.
60l max for all the contain-
ers which must be con-
ductors and connected to
the equipotential connec-
tion (supplied)
Prohibition of spraying of prod-
ucts with a resistivity below 1000
Ω
.cm.
Incorrect earthing
The equipment must be earthed
by means of at least 2 points: its
electrical supply and a dedi-
cated wire (supplied)
The operator must periodi-
cally check the quality of
the earthing outlets
DES07178
Registered Design
3