3. TROUBLESHOOTING 

CHART 

TROUBLE 

CAUSE 

SOLUTION 

Overpressure at the fluid 
regulator outlet. 

Air pilot pressure too high. 

Decrease air pilot pressure. 

Improper fluid proofness 
between seat and ball. 

Clean or replace 

Material pressure too high 
upstream of the regulator. 

Decrease the pump air supply. 

No material coming out from 
the regulator. 

Insufficient air pilot pressure. 

Increase air pilot pressure. 

Ball blocked on the seat. 

Clean and reinstall. 

Irregular flow rate. 

Too much pulsation in the fluid 
network. 

Check fluid network. 

Improper proofness between 
seat an ball. 

Clean or replace. 

Material leakage along the 
regulator hat. 

Defective diaphragm. 

Replace. 

Loosen lower spring support. 

Tighten. 

4. DISASSEMBLY 

 

SEAT (3) REPLACEMENT 

Unscrew fluid inlet fittings (5 and 2) 

Remove conical spring (17), ball (18) and seal (6). 

Remove seat (3) and flat seal (4). 

Replace seals. 

Clean parts with white spirit solvent. 

Reinstall parts in reverse. Be certain the flat seal is properly located. 

 

The seat is reversible. When servicing the first time it can be installed upside down.  It 
will have to be replaced only at second servicing. 

 

DIAPHRAGM (7) REPLACEMENT 

Unscrew the 6 screws (9). 

Remove hat (21). 

Unscrew nut (8). 

Remove lower washer (10). 

Remove diaphragm (7). 

Clean parts with white spirit solvent. 

Reassemble parts in reverse. 