52
DRT7115
E - 2022/11
Member of EXEL group
6.4.7.
Procedure C3: Replacement of the high voltage cascade
•
Step 1
: First, remove the trigger (
).
•
Step 2
:
Loosen the 4 screws (
A
) fastening the
barrel on the handle with a 2mm Phillips
screwdriver.
•
Step 3
:
Unscrew, manually or with a small flat
pliers, the three connection (
B
) wires of the
high voltage unit, pull carefully the contacts
towards the back.
•
Step 4
:
Remove the high voltage contact in
front of the barrel
).
Withdraw the high voltage unit.
WARNING : Attention with the colors (terminal
1: black, terminal 2: green, terminal 3: pink).
To reassemble, follow the steps in reverse order.
Replace the high-voltage cascade.
Coat the
cascade with dielectric grease
(P/N #
H1GSYN037) then insert it into its housing.
Push the cascade fully into the barrel.
Connect the three wires and tighten the screws.
Check the wear of the o-rings, replace if necessary.
1
3
2
A
B