Index revision : D - March 2018
11
7115
2.4. Maintenance rules
• Regularly maintain and repair the electrostatic projection equipment according to the
instructions contained in this user’s manual.
• Only use metal containers to hold the cleaning liquids and connect to ground according
to a safe procedure.
• Before any maintenance procedure:
1 Turn off the control module.
2 Verify that the air and paint circuits are no longer pressurised.
3 Bleed the paint circuit.
4 All energy sources must be locked out.
• Clean the gun either in their dedicated spots with mechanical ventilation or by using
cleaning liquids with a flash point at least 15°C higher than ambient temperature.
• Opt to use non-flammable cleaning products.
• Do not restore electrical power supply as long as the air cap and nozzle have not been
correctly remounted onto the gun.
• Never soak or immerse the gun in the solvent. The operator is able, as needed, to use a
cloth soaking in solvent in order to clean the gun and then immediately dry it to avoid sol-
vent from entering the gun.
WARNING : Never spray solvent when the control module is turned on and/or when the switch
placed at the back of the gun is in the “I” position
.
WARNING : Shutting off the compressed air supply line does not prohibit triggering high voltage
should the trigger be activated.
• The operator must have been trained by a
SAMES KREMLIN
company or else by the
Distributors it has certified for this purpose, in order to carry out the
Nanogun Airmix
®
gun
maintenance operations.
WARNING : It is strictly prohibited to use solvents derived from halogenated hydrocarbons as
well as products containing these solvents in the presence of aluminium or zinc.
Failure to comply with these guidelines exposes the user to the risks of explosion.