Disassembly / Reassembly Operation
27/10/2020
582136110-SH0060-indA-EN.docx
36
11
Disassembly / Reassembly Operation
ATTENTION
Before any pump maintenance or service work
performed can be imperative to follow the
depressurization procedure and the safety instructions.
ATTENTION
The equipment is subject to the ATEX directive and must
not be modified under any circumstances.
Failure to comply with this recommendation does not
engage our responsibility.
Before each reassembly
Clean the parts with the appropriate cleaning solvent.
Fit new seals if necessary, after greasing them.
Grease the piston and the inside of the cylinder to avoid
damaging the seals.
Fit new parts if necessary.
Greases and thread lockers
designations
Index
Instruction
Description
Part number
A 1
PTFE grease
'TECHNI LUB' grease
(10 ml / 0.0026 US gal)
560.440.101
A 2
Anti-seize grease
Grease box (450 g / 0.99 lb)
560.420.005
C 1
Medium strength
Aneorobic Pipe sealant
Loctite 5772 (50 ml / 0.013 US gal)
554.180.015
C 3
Medium strength
Aneorobic Adhesive
Loctite 270 (50 ml / 0.013 US gal)
554.180.004