Use of the product
32
Adjustment of the suction
valve ball cage screw
Depending upon the fluid viscosity to be pumped, adjust the height
of the screw (19C) to increase the ball up motion.
Lock the screw on the lock nut (19B).
(For a full description of spare parts, see Part 12 - Spare Parts)
19B
19A
19C