38
Member of Exel group
DRT582094110
C - 2022/11
5.2. Installation
The 1 m / 39.37’’ distance indicated in this diagram is given as for information purposes only and hold
harmless to Sames.
The exact delimitation of the zones is the express responsability of the user, depending on the materials
used, the environment and the conditions of use.
The 1 m / 39.37’’ distance can be modified if the analysis conducted by the user requires it.
Using a high-pressure hose, connect the guns’ paint fitting to the pump. Tighten the fittings securely.
It is imperative that the gun’s fluid hose be conductive.
A - Zone 1 (Z1) or zone 2 (Z2) explosive zone: spray booth
B - Non-explosive zone
A
Inside the spray
booth Zone 1
Outside the spray
booth
Safe zone
B
1m
Summary of Contents for SFlow
Page 1: ...Instruction manual DRT582094110 C 2022 11 SFlow...
Page 27: ...27 Member of Exel group DRT582094110 C 2022 11 M 1 4 NPSM P N 135 740 445 135 740 447...
Page 32: ...32 Member of Exel group DRT582094110 C 2022 11 M 1 2 JIC P N 135 741 427...
Page 34: ...34 Member of Exel group DRT582094110 C 2022 11 M 1 4 NPSM P N 135 746 449...