8. Cleaning
According to the frequency of use and in all the cases at the end of each cycle
• Stop the atomizer and switch off the power supply.
Before any operation, refer to the health and safety rules (
).
WARNING : Always wear safety goggles.
Whenever solvent is handled, rubber gloves must be worn.
Work in a well ventilated area whenever solvent is used.
WARNING : It is imperative to pass a rag soaked with water on the atomizer before cleaning it
using a rag and an approved cleaning product. Do not use a manual solvent gun.
Under no circumstances must the atomizer or any of its components be sprayed with solvent or water at
high or low pressure.
WARNING : SAMES Technologies disadvises the use of protective plastic sheets.
If, despite this warning, plastic sheets are used to protect the atomizer, do not
choose ”anti-static” sheets as these conduct electricity and will short-circuit the
high voltage if they are used to protect insulating parts such as the atomizer body.
Sames
Technologies advises
the use of textile cover or dielectric grease.
WARNING : In all the cases, the protections installed must be insulating to avoid any risk of over-
consumption in current. This is why, these protections must be regularly replaced
in order to keep an acceptable leakage current by the high voltage generator (of HV
defaults will be able to appear if clogging in painting is too important).