1.4. Precautions for use
1.4.1. General
The equipment at your disposal is for professional use only. It must be used only for the purpose for
which it was intended or designed.
Read all operating instructions and labels carefully before operating the equipment.
Personnel using this equipment must have been trained in its use.
The workshop manager must ensure that the operators have fully understood all the instructions and
safety rules of this equipment and other elements and accessories of the installation.
Misuse or improper operation can cause serious injury.
Do not modify or transform the equipment. Parts and accessories must only be supplied or approved
exclusively by
Sames
.
The equipment must be checked periodically. Defective or worn parts must be replaced.
Never exceed the maximum working pressures of the equipment components.
Always respect the laws in force regarding security, fire, electricity of the destination country of the
equipment.
Only use products or solvents that are compatible with the parts in contact with the material (see
material manufacturer’s data sheet).
1.4.2. Safety devices
ATTENTION
Safety devices are set up for safe use of the equipment.
The manufacturer cannot be held responsible for any bodily injury as well as failures and / or damage to
the equipment resulting from the destruction, hiding or total or partial removal of the safety devices.
1.4.3. Pressure hazards
Safety requires that a
pressure relief-air
shut-off valve must be installed in the pump motor supply
system to release trapped air when the supply is shut off.
Without that precaution, residual air from the motor may cause the pump to operate and cause a serious
injury.
Also, a
fluid drain valve
must be installed on the fluid system so that it can be drained (after shutting
off motor air and decompressing it) before any operation on the equipment. Theses valves must remain
closed for the air and opened for the fluid during the intervention.