Index revision : C - March 2016
21
7105
7. Installation
WARNING : Before any work, please refer to the installation rules (
see § 2.2 page 8
).
7.1. With piston pump for all versions
The paint supply must be installed in a well-ventilated area.
The paint container and pump must always be electrically grounded.
The dump hose must be submerged in the paint.
WARNING : The paint supply pump:
• must have a maximum ratio of 1:1.
• and the pump air supply must be fitted with a safety valve limiting pressure to 6.5 bar
max.
1
General air supply
2
Air filter
3
Main air valve
4
Pump air shut-off valve
5
Air pressure regulator
6
Spraying air filter/regulator
7
Spraying air valve
8
GNM 6080 control module
9
Spray gun air supply hose
10
NANOGUN-MV Spray Gun
11
Low voltage power supply cable
12
Pump (complies with ATEX Directive)
13
Dump valve
14
Product filter
15
Product supply hose
16
Mains power cable (220V + ground) or
(115V + ground)
17
Warning sign
18
Potentially explosive atmosphere
19
Area with no risk of explosion
8
10
18
19