Index revision : C - March 2016
39
7105
10.11. High voltage cascade
•
Step 1
: Remove the trigger (
see § 10.8 page 36
), remove the paint needle.
•
Step 2
: Loosen the 4 screws fastening the barrel
on the handle with a 2mm Phillips screwdriver.
•
Step 3
: Unscrew, manually or with a small flat
pliers, the three connection wires of the high
voltage unit, pull carefully the contacts towards
the back.
•
Step.4
: Remove the high voltage contact in front
of the barrel (
see § 10.5 page 34
). Withdraw the
high voltage unit.
WARNING : Attention with the colors (terminal 1:
black, terminal 2: green, terminal 3: pink).
To reassemble, follow the steps in reverse order.
Replace the high-voltage cascade.
Coat the cascade with red dielectric lubricant
(P/N #
H1GSYN037) then insert it into its housing.
Push the cascade fully into the barrel. Connect the three wires and tighten the screws. Check the wear
of the o-rings, replace if necessary.
Step 3
Step 4
Step 2
1
2
3