Index revision : C - March 2016
61
7105
13.13. Options for NANOGUN-MV Low Pressure spray guns
13.13.1. Fan Spray
Air Caps
(*)
Level 1: Standard preventive maintenance.
Level 2: Corrective maintenance.
Level 3: Exceptional maintenance.
13.13.2. In-line product filters
These small filters are fitted in the spray gun handle (with HR models).
WARNING : The filter is delivered with a 6mm screen as standard. Before installation of low
pressure models, you are advised to replace the screen nr 6 from the initial design
with a screen nr 12.
With LR models,
it is necessary ro remove the fitting F 3/8 NPT- M1/2 JIC located at the pump outlet
and to replace it by the filter.
Part number
Description
Qty
Unit of
sale
Spare Part
Level (*)
737549
Air Cap (fan spray)
Option
1
1
737550
SPE Air Cap (narrow fan spray)
Option
1
1
737552
SPL Air Cap (broad fan spray)
Option
1
1
Description
Part number
Versions
Filter (Male-Female 1/2 JIC)
155010100
LP HR
Screen nr 12
129609909
DES04202