70
Member of Exel group
DRT7145
C - 2022/11
8. Connections
8.1. CAN Inputs / Outputs connector
8.2. Vib / Smoke connector
8.3. 100 / 240 VAC power supply connector
8.4. Circular connector to Inogun A projector or Inogun M spray gun
The high voltage unit of the projector or the spray gun is connected by a low voltage cable to the module
Inobox
.
This cable is connected to the module via a circular connector.
Pin
Description
Designation
Characteristics
-
Shielding
0V
A
0V Trigger
0V dry contact pilot for ON / OFF high voltage
Solder wire size max. 24 AWG
/ max. 0,25 mm²
for Pilot Dry Contact
B
COM Trigger
Cathode input of the pilot optocoupler On / Off high
voltage
C
0V CLEANING
0V for dry pilot contact On / Off cleaning
Solder wire size max. 24 AWG
/ max. 0,25 mm²
for Pilot Dry Contact
D
COM CLEANING
Cathode input of the pilot optocoupler On / Off
cleaning
E
N.O FAULT relay
Output of the NO dry contact (normally open) of the
fault relay
Solder wire size max.
24 AWG / max. 0,25 mm²
Dry contact relay:
30VDC 0.5A
F
N.C FAULT relay
Output of the NC contact (normally closed) of the
fault relay
G
COMMON FAULT relay
0 V
H
CAN H
Data bus CAN signal H
Solder wire size
24 AWG / max. 0,25 mm²
J
CAN L
Data bus CAN signal L
K
CAN shielding
0V
L
NC
-
M
NC
-
Pin
Description
Designation
Characteristics
1
NEUTRAL VIBRATOR
N.O. RELAY NEUTRAL VIBRATOR
Vibrator relay
100V /240V / 50W
Contacts 4A / 250VAC/DC
max.18 AWG
2
VIBRATOR PHASE
N.O. RELAY PHASE VIBRATOR
3
Ground (G/Y)VIBRATOR
Ground / 0V
4
Pin
Description
Designation
Characteristics
1
NEUTRAL POWER SUPPLY
Neutral
Power supply
100VAC to 240 VAC / 47Hz -
63Hz
Contacts 4A / 250 VAC / DC
max.18 AWG
2
POWER SUPPLY PHASE
Phase
3
GROUND (G/Y)
POWER SUPPLY
NC
Ground / 0V
4