1.7. Important recommendations
1.7.1. Ventilation
Do not start the powder application with the
Inogun A
projector until the spray booth ventilation system is switched
on. If the ventilation is switched off, toxic substances or dust may remain in the spray booth and cause a risk of fire,
poisoning or irritation.
1.7.2. O-ring seals
Use the seals recommended in this manual.
1.7.3. Safety devices
When installing the projector, safety devices must be provided.
• Detection of control system faults.
• Detection of high voltage surges associated with the
Sames
HV generator.
• Detection of air pressure drops.
• Detection of ventilation failure.
• Detection of variations in ventilation flow rates.
• Detection of fire.
Failure to install safety devices could result in a risk of fire, expose the personnel to serious injury and
damage the equipment.
The electrostatic projection systems must be equipped with an automatic fire extinguishing
system (according to § 5.2.5 in standard EN 50177).
1.7.4. Mechanical collision
The guarantee does not cover damage resulting from the operating environment (for example: collision with the
robot).
1.7.5. Ambient temperature
The atomizer is designed to normally operate at an ambient temperature comprised between 0°C and + 40°C.
The storage temperature must never 60°C.
Summary of Contents for inocoat Inogun A
Page 1: ...Instruction manual DRT7133 D 2023 01 Inogun A FCC Standard and Robotic Versions...
Page 78: ...78 Member of Exel group DRT7133 D 2023 01 10 Appendices 10 1 Preventive maintenance plan...
Page 82: ...79 DRT7133 D 2023 01 Member of Exel group 10 2 EU and UK declarations of conformity...
Page 87: ...Sames 13 Chemin de Malacher 38240 Meylan France 33 0 4 76 41 60 60...