24
Member of Exel group
DRT7133
D - 2023/01
4. Diagrams
4.1. Electrical connections
Pin
10-pin connector
Inocontroller or Inobox side
Pin
4-pin connector
Inogun A side
1
Primary 1 HVU
1
HVU 1-Primary
2
Not connected
3
HVU 2-Primary
2
HVU 2-Primary
4
Not connected
5
Ground
3
Ground
6
Not connected
7
I HVU return
4
I HVU return
8
9
Inogun A recognition bridge
automatic
10
1
2
3
4
4
3
2
1
5
6
7
8
9
10
------------------------------->
-------->
-------->
------------------->
------------>
------------------------------->
------------------------------->
<------
<------
<-------
<-------
DES07281
Inocontroller
side
Yellow
White
Green
Marron
360° shielding connection via
the M8 connector ferrule
Projector side
360° shielding connection via
the M16 connector ferrule
White
Green
Brown
Yellow
White
Green
Brown