5.2.2. Procedure for mounting the counter-electrode
The
Inogun M
can be equipped with an optional counter-electrode (
).
• Switch off high voltage,
•
Step 1
: Unscrew the 2 screws (1 and 2)at the back of
the gun.
•
Step 2
: Slide the hook towards the front of the gun.
•
Step 3
: Insert the conductive hook (3), slide it to the
stop and then tighten the 2 KA 30 x 20 screws (4) to
a torque of 0.65 N.m.
•
Step 4
: Place the counter-electrode (1) on the nozzle
nut of the gun and slide it until the banana plug (2) is
in contact with the conductive hook (3).
• Switch on high voltage.
1
2
1
2
3