DESCRIPTION

The Battery Guard Waterproof BGW40/60 (hereafter 
referred to as the BGW) is an intelligent, user-
programmable, fully waterproof battery guard.  
The BGW has additional options for a remote off 
switch and an alarm output for connecting a buzzer, 
LED strip or relay. To ensure low losses, the BGW is 
provided with two threaded rod and nut connections; 
input+ and . The other connections (Minus-, 
Remote Off-, Config-input and Status/alarm output) 
are connected via 6.3 mm faston connectors.  
The BGW is equipped with a bright status LED 
displaying the different functional stages. The BGW 
features an “automatic board system detection”, 
this enables to automatically detect if the BGW is 
connected to a 12 V or a 24 V system.

INSTALLATION

Install the BGW on a cooling (metal) surface allowing 
to dissipate the heat generated. Use a maximum 
cable length of 50 cm between the battery and the 
BGW will ensure accurate monitoring the battery 
voltage.

Please note!

•  The product may only be installed by qualified 

electricians who are fully aware of the require-
ments for working with high battery voltages.

•  The use of poor/ bad connection material and/or 

wires that are too thin can damage the BGW.

•  A short circuit between the battery’s positive and 

negative terminals can cause serious damage to 
the system.

•  Always use fuses of the correct value.
•  Use a 1.5 mm

2

 cable with 1 A fuse from the 

battery (-) to the BGW for the negative (–) 
connection. Use this connection only for the BGW!

WIRING DIAGRAM (please see last page)

OPERATION

Input voltage protection

The input voltage protection values (undervoltage 
threshold, undervoltage reset, overvoltage threshold 
and overvoltage reset) can be set by the user.  
Please see “CONFIGURE/Programming” how to  
set these values.

Undervoltage

If the BGW’s input voltage drops below the 
undervoltage threshold for 15 seconds, the status/
alarm output will turn on. The LED will also indicate 
undervoltage. The BGW will shut down one minute 
later and the alarm output and LED will turn off.
When the BGW’s input voltage exceeds the reset 
threshold for 5 seconds, the BGW will turn back 
on, and the LED will indicate that the BGW is active 
again.

Overvoltage

The BGW will shut down if the input voltage exceeds 
the overvoltage threshold for 0.5 seconds. The status/
alarm output and LED will flash/switch with a 
frequency of 1 Hz.

Overcurrent protection

The current through the BGW is constantly monitored. 
If an excessive current flows through the BGW for 
too long, the BGW will shut down to prevent damage 
to both the BGW and the connected equipment.  
The BGW will turn on again after 1 minute.

Temperature protection

The BGW will shut down immediately if its 
temperature exceeds 85 °C. The LED will indicate 
a fault. The BGW will turn on again after 1 minute if 
the temperature has dropped below 75 °C.

Ground Loss protection

The BGW will shut down if it detects that the minus 
(–) is disconnected on the supply (battery) side.  
The LED will indicate a fault. The BGW will turn on 
again after 1 minute.

Remote off

A switch can be installed between the OFF input and 
the minus (–) to manually disable the BGW output. 
The BGW will shut down immediately when the 
connection is made. The BGW will turn on when  
the connection has been disconnected.

LED

The LED has two functions. One is to indicate the 
BGW’s status. The different stages are explaned in 
the LED STATUS below. The other is to configure/

OWNERS MANUAL

EN

Summary of Contents for BGW 40

Page 1: ...GW 40 BGW 60 Battery Guard Waterproof BATTERY GUARD WATERPROOF Please read this manual before operating your Battery Guard Owners Manual Gebruiksaanwijzing Bedienungsanleitung Mode D Emploi Manual del propietario ...

Page 2: ...dervoltage reset overvoltage threshold and overvoltage reset can be set by the user Please see CONFIGURE Programming how to set these values Undervoltage If the BGW s input voltage drops below the undervoltage threshold for 15 seconds the status alarm output will turn on The LED will also indicate undervoltage The BGW will shut down one minute later and the alarm output and LED will turn off When ...

Page 3: ...ly short again to set the correct position from the programming table The LED will light up as feedback At that point program position 1 is selected The user can briefly short make the connection again to select programme position 2 etc etc If no connection is made for approx 4 seconds the LED will display the set state again Example programme position 4 is set by a user the LED will blink 4 times...

Page 4: ...FASTON CONNECTIONS Minimum wire diameter 1 5 mm2 Faston plug 6 3 mm MECHANICAL Mounting hole Ø 4 2 mm Distance between mounting holes centre to centre 50 mm 1 mm Weight 155 g Dimensions H W L 32 72 62 mm IP Code IP66 Housing material PU552 Housing colour Black Cooling concept Convection and conduction GENERAL Operational ambient temperature 10 C 40 C Storage temperature 25 C 85 C Operational air h...

Page 5: ...ingsbeveiliging De waarden van de ingangsspaningsbeveiliging onderspanning drempel onderspanning reset overspanning drempel en overspanning reset zijn door de gebruiker instelbaar Hoe dit te doen is te lezen in het onderdeel Configureren Programmeren Onderspanning Wanneer de ingangsspanning van de BGW 15 seconden onder de onderspanning drempel waarde is zal de status alarmuitgang inschakelen Ook z...

Page 6: ...beurd is moet de verbinding verbroken worden Om het juiste positienummer in te stellen moet dezelfde verbinding weer kort gemaakt worden de led zal als terugkoppeling oplichten Op dat moment is programma positie 1 gekozen Wanneer de gebruiker nogmaals kort de verbinding maakt is programma positie 2 gekozen etc etc Wanneer er 4 seconden geen verbinding gemaakt is zal de led de ingestelde stand nogm...

Page 7: ...uikte kabeldiameter AANSLUITINGEN FASTON Minimale aderdikte 1 5 mm2 Faston stekker 6 3 mm MECHANISCH Montagegat Ø 4 2 mm Afstand tussen montagegaten hart op hart 50 mm 1 mm Gewicht 155 g Dimensies H B L 32 72 62 mm IP Code IP66 Behuizing materiaal PU552 Behuizing kleur Zwart Koelconcept Convectie en geleiding ALGEMEEN Operationele omgevingstemperatuur 10 C 40 C Opslag temperatuur 25 C 85 C Operati...

Page 8: ...icherung von der Batterie zum BGW Diesen Anschluss nur für die BGW verwenden SCHALTPLAN SIEHE LETZTE SEITE FUNKTIONSWEISE Betriebsspannungsschutz Die Werte für den Betriebsspannungsschutz Schwellwert für die Unterspannung Wiedereinschal tung nach Unterspannung Schwellwert für die Überspannung und Wiedereinschaltung nach Überspannung können vom Benutzer eingestellt werden Wie das geht wird im Kapit...

Page 9: ...schen Programmeingang CONFIG und Minus Anschluss hergestellt werden 2 Sekunden nach der Herstellung der Verbindung blinkt die LED einmal auf Gleich danach muss die Verbindung getrennt werden Zum Einstellen der korrekten Positionsnummer muss die gleiche Verbindung erneut kurz hergestellt werden die LED leuchtet als Rückmeldung auf In diesem Moment wurde Programmposition Nr 1 gewählt Wenn der Nutzer...

Page 10: ...ASTON STECKERANSCHLÜSSE Mindestquerschnitt 1 5 mm2 Faston Stecker 6 3 mm MECHANISCH Montageloch Ø 4 2 mm Abstand zwischen Montageloch und Mittelpunkt zu Mittelpunkt 50 mm 1 mm Gewicht 155 g Abmessungen H B L 32 72 62 mm IP Code IP66 Gehäusematerial PU552 Gehäusefarbe Schwarz Kühlmethode Konvektion und Leitung ALLGEMEIN Betriebsumgebungstemperatur 10 C 40 C Lagertemperatur 25 C 85 C Betriebsluftfeu...

Page 11: ...on négative Utilisez cette connexion uniquement pour le BGW SCHÉMA DES CONNEXIONS Veuillez consulter la dernière page MODE DE FONCTIONNEMENT Protection contre la surtension d alimentation L utilisateur peut programmer les valeurs de protection contre la surtension d alimentation le seuil de sous tension la réinitialisation de la sous tension le seuil de surtension et la réinitialisation de surtens...

Page 12: ...CONFIG et la borne négative La LED 1 se met à clignoter dès qu un contact a été établi pendant 2 secondes Dès que cela se produit le contact doit être rompu Pour programmer le numéro de position adéquat il faut à nouveau brièvement rétablir le contact La LED s allume en retour À ce moment la position de programmation n 1 est sélectionnée Lorsque l utilisateur établit à nouveau brièvement le contac...

Page 13: ...CHEMENTS FASTON Épaisseur minimale d âme 1 5 mm2 Connecteur Faston 6 3 mm MÉCANIQUE Orifice de montage Ø 4 2 mm Distance entre les orifices de montage centre à centre 50 mm 1 mm Poids 155 g Dimensions H l P 32 72 62 mm Code IP IP66 Matériau du boîtier PU552 Couleur du boîtier Noir Mode de refroidissement Convection et conduction GÉNÉRALITÉS Température ambiante de fonctionnement 10 C 40 C Températ...

Page 14: ...avor vea la última página FUNCIONAMIENTO Protección de la tensión entrada El usuario puede configurar los valores de la protección de la tensión de entrada umbral de subtensión reseteo de subtensión umbral de sobretensión y reseteo de sobretensión Para hacer esto consulte el apartado CONFIGURAR Programación Subtensión Cuando la tensión de entrada del BGW esté debajo del valor umbral de subtensión ...

Page 15: ... una conexión entre la entrada de CONFIG y el min Una vez se haya establecido la conexión durante 2 segundos el LED parpadeará una vez Tan pronto como esto ocurra deberá interrumpirse la conexión A fin de ajustar el número de posición correcto deberá cortarse de nuevo la misma conexión el LED se encenderá como retroalimentación En ese momento se elige la posición de programa núm 1 Tan pronto como ...

Page 16: ...XIONES FASTON Grosor mínimo de los hilos del cable 1 5 mm2 Enchufe Faston 6 3 mm MECÁNICO Orificio de montaje Ø 4 2 mm Distancia entre el orificio de montaje y distancia de centro a centro 50 mm 1 mm Peso 155 g Dimensiones Al An Pr 32 72 62 mm Código IP IP66 Material de carcasa PU552 Color de la carcasa Negro Modelo de enfriamiento Convección y conducción GENERAL Temperatura ambiental de funcionam...

Page 17: ...WIRING DIAGRAM AANSLUITSCHEMA SCHALTPLAN SCHÉMA DES CONNEXIONS ESQUEMA DE CONEXIÓN ...

Page 18: ...5 1507 BA ZAANDAM The Netherlands Declares that the following products PRODUCT TYPE Battery Guard Waterproof BRAND Samlex Standards to which conformity is declared EN 61000 6 2 2005 EN 61000 6 3 2007 Signed Marcel van Veen Date 20 May 2022 Authority Managing Director BGW 40 BGW 60 ...

Page 19: ...BGW 40 60 300522 www samlex com www samlex solar com ...

Reviews: