CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
WARNING - TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK,
DO NOT EXPOSE THIS APPLIANCE TO RAIN OR MOISTURE. THERE
ARE NO USER SERVICEABLE PARTS INSIDE REFER TO QUALIFIED
SERVICE PERSONNEL.
IMPORTANT SAFETY INSTRUCTIONS
1) It is recommended that you return your power supply to a qualified Samlex dealer for any service
or repair. Incorrect assembly may result in electric shock or fire.
2) To reduce the risk of electric shock, unplug the power supply from outlet before attempting any
maintenance or cleaning. Turning off the ON/OFF switch controls will not reduce this risk.
3) An extension cord should not be used unless absolutely necessary. If an extension cord must be
used make sure that the pins on the plug are the same number, size and shape as those of the
original power supply plug.
WARNING!
Your power supply should be grounded to reduce the risk of electric shock. The power supply
is equipped with a grounding conductor and grounding plug.
The cord must be plugged into an outlet that is properly installed and grounded in accordance with
all local codes and ordinances. Never alter the AC cord of plug provided. If the cord will not fit the
outlet, have a proper outlet installed by a qualified electrician. Improper connection can result in
risk of electric shock.
2
PRECAUTIONS
The power supply must be placed in an area that will
allow air to flow freely around the unit. Keep the power
supply away from moisture and water.
TROUBLESHOOTING
Probable cause
Suggested Remedy
Fuse is blown
Check fuse and if blown, replace with
similarly rated fuse.
Unit has been short circuited Remove short circuit; unit will auto-
matically restart.
Input voltage is erratic
Check input voltage for abnormally high
or low voltage fluctuation and stabilize.
Connections are loose
Check and secure all output terminal
connections.
5
Problem: no output power
All manuals and user guides at all-guides.com